首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Detecting myocardial ischemia with 2-D CVIB imaging method--an in vivo animal experiment study
作者姓名:JIANG Yong  BAI Jing  YING Kui  CHENG Kezheng  YU Can
作者单位:Department of Biomedical Engineering, Tsinghua Univeristy, Beijing 100084, China,Department of Biomedical Engineering, Tsinghua Univeristy, Beijing 100084, China,Department of Biomedical Engineering, Tsinghua Univeristy, Beijing 100084, China,Fuwai Hospital, Beijing 100037, China,Department of Biomedical Engineering, Tsinghua Univeristy, Beijing 100084, China
摘    要:A 2-D cyclic variation of integrated backscatter (CVIB) imaging method was established for detecting myocardial ischemia. To demonstrate the feasibility and validity of this method, animal experiments were conducted. Acute myocardial ischemia was induced by occluding left anterior descending coronary artery in 10 anesthetized open-chest dogs. While scanning the normal hearts and the ischemic hearts with a B scanner, digital radiofrequency data were acquired by a real-time acquisition system in synchronism. The offline analysis to the radio-frequency signal with the 2-D CVIB imaging method was performed to verify the consistency between the imaging result and the design of the experiment. In addition, 4 dogs in experiment were treated with the heart pacemaker in order to investigate the influence of changing in heart rate on the detection of ischemic myocardium with the proposed method. The experimental result showed that the 2-D CVIB imaging method succeeded in detecting the ischemic myocardium and is a new non-invasive way for the cardiologists to both quantitatively and visually evaluate the contractile performance of the myocardium.

关 键 词:integrated  backscatter  (IB)    myocardial  ischemia    cyclic  variation  of  integrated  backscatter  (CVIB)  

Detecting myocardial ischemia with 2-D CVIB imaging method--an in vivo animal experiment study
JIANG Yong,BAI Jing,YING Kui,CHENG Kezheng,YU Can.Detecting myocardial ischemia with 2-D CVIB imaging method--an in vivo animal experiment study[J].Progress in Natural Science,2004,14(11):991-995.
Authors:JIANG Yong  BAI Jing  YING Kui  CHENG Kezheng  YU Can
Institution:1. Department of Biomedical Engineering, Tsinghua Univeristy, Beijing 100084, China
2. Fuwai Hospital, Beijing 100037, China
Abstract:A 2-D cyclic variation of integrated backscatter (CVIB) imaging method was established for detecting myocardial ischemia. To demonstrate the feasibility and validity of this method, animal experiments were conducted. Acute myocardial ischemia was induced by occluding left anterior descending coronary artery in 10 anesthetized open-chest dogs. While scanning the normal hearts and the ischemic hearts with a B scanner, digital radiofrequency data were acquired by a real-time acquisition system in synchronism. The offline analysis to the radio-frequency signal with the 2-D CVIB imaging method was performed to verify the consistency between the imaging result and the design of the experiment. In addition, 4 dogs in experiment were treated with the heart pacemaker in order to investigate the influence of changing in heart rate on the detection of ischemic myocardium with the proposed method. The experimental result showed that the 2-D CVIB imaging method succeeded in detecting the ischemic myocardium and is a new non-invasive way for the cardiologists to both quantitatively and visually evaluate the contractile performance of the myocardium.
Keywords:integrated backscatter (IB)  myocardial ischemia  cyclic variation of integrated backscatter (CVIB)  animal study
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《自然科学进展(英文版)》浏览原始摘要信息
点击此处可从《自然科学进展(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号