孔雀绿对电子辐照响应研究
引用本文:郑丹,蒋波,伍登学,刘强,孙鹏,何捷,万喻平.孔雀绿对电子辐照响应研究[J].四川大学学报(自然科学版),2010,47(2):356-360.
作者姓名:郑丹  蒋波  伍登学  刘强  孙鹏  何捷  万喻平
作者单位:1. 四川大学物理学院和辐射物理及技术教育部重点实验室,成都,610064
2. 四川大学国家生物医学材料工程技术研究中心,成都,610064
3. 成都市产品质量监督检验院,成都,610041
基金项目:国家自然科学基金(10875083);四川省应用技术研究与开发项目(07FG001-025)
摘    要:一种以聚乙烯醇缩聚物为基质,以多芳氨基甲烷类化合物(隐色孔雀绿)为染色物质和卤代物为协同剂制成的辐射变色膜.经电子辐照后其颜色由无色透明变为绿色.辐照后吸收光谱显示其最强吸收峰出现在629 nm附近.研究表明:吸光度响应与电子注量成线性关系,电子能量和分次辐照对其有明显影响,在某注量率范围内吸光度存在辐照后效应,24 h后趋于稳定,且膜厚与响应成正相关性.该体系辐射变色膜可作为电子束的辐照变色薄膜剂量计.

关 键 词:孔雀绿  电子辐射  吸收光谱  变色薄膜  辐照变色薄膜剂量计

Study on the response of malachite green to the electronic irradiation
ZHENG Dan,JIANG Bo,WU Deng-Xue,LIU Qiang,SUN Peng,HE Jie,WAN Yu-Ping.Study on the response of malachite green to the electronic irradiation[J].Journal of Sichuan University (Natural Science Edition),2010,47(2):356-360.
Authors:ZHENG Dan  JIANG Bo  WU Deng-Xue  LIU Qiang  SUN Peng  HE Jie  WAN Yu-Ping
Institution:College of physical science and Technology, Sichuan University;Engineering Research Center in Biomaterials, Sichuan University;College of physical science and Technology, Sichuan University;College of physical science and Technology, Sichuan University;College of physical science and Technology, Sichuan University;College of physical science and Technology, Sichuan University;Product Quality Supervision and Inspection Centre in Chengdu
Abstract:A radiochromic film is prepared by using a polymer as the base and doping an organic dye (Malachite Green) and an organic halide. This radiochromic film is a clear transparent solid film, but it becomes blue after irradiated by electronic irradiation. As shown in the UV-VIS spectrum of irradiated films, the peak in visual region locates about 629 nm. Research shows that: there is a linear relationship between absorbance response and electron fluency . Electronic energy and the continuous irradiation or fractured irradiation make a notable impact on the radiochromic film. The absorbance response have small changes in a range of electron fluency rate. 24 hours after the film stability. The relationship between thickness of radiochromic film and absorbance response is a positive correlation. The radiochromic film can be used as electronic radiation dosimetry.
Keywords:malachite green  electronic radiation  absorption spectrum  radiochromic film  radiochromic film dosimeters