摘    要:本文采用SeSO2-3-KIO3体系示波极谱催化波法测定了鸡蛋中的硒。试样经HNO3-HClO4混酸消化处理,用浓盐酸还原为Se(Ⅳ)后,进行示波导数极谱测定。该方法线性范围为0.05~2.50μg/L,回收率95%,对样品测量的相对标准偏差为4.76%。

关 键 词:极谱催化波  鸡蛋  

Determination of Selenium in Egg by Catalytic Oscillopolarography of SeSO 2- 3-KIO 3 System
Jia Fengzhi Li Yaqing Xie Ping Yang Baolin. Determination of Selenium in Egg by Catalytic Oscillopolarography of SeSO 2- 3-KIO 3 System[J]. Journal of Hebei University (Natural Science Edition), 1997, 0(1)
Authors:Jia Fengzhi Li Yaqing Xie Ping Yang Baolin
Abstract:A catalytic oscillopolarography of SeSO 2- 3-KIO 3 system was applied for the determination of selenium in egg. Sample was applied by HNO 3-HClO 4 mixture, the selenium was reduced to Se(Ⅳ) in concentrated HCl, and then determind by catalytic oscillopolarography. The linear range, recovery and RSD of the method were 0.05~2.50 μg/L, 95% and 4.8% respectively.