关于尘埃粒子计数器采样管长度的探讨
引用本文:许钟麟,沈晋明.关于尘埃粒子计数器采样管长度的探讨[J].同济大学学报(自然科学版),1998,26(4):447-452.
作者姓名:许钟麟  沈晋明
作者单位:中国建筑科学研究院空调研究所!北京,100031(许钟麟),同济大学热能工程系!上海,200092(沈晋明)
基金项目:国家自然科学基金!59578017
摘    要:在美国联邦标准FS209E中对尘埃粒子计数器采样管的长度和采集的气溶胶在采样管中的流动时间提出了要求.据此通过给出的简便图表的计算,提出了不同流量粒子计数器、不同的粒径分档的允许管长,并推荐给我国标准GB5073-98.

关 键 词:洁净室技术  气溶胶采样  粒子计数器  采样管允许长度

Length of Transit Tube in a Particle Counter
Xu Zhonglin.Length of Transit Tube in a Particle Counter[J].Journal of Tongji University(Natural Science),1998,26(4):447-452.
Authors:Xu Zhonglin
Abstract:The transit tube length and its transit time in a particle counter is set as a demand in the American Fedend Standard 209E. The pendssible lengthes of transit tubes for different particle size ranges and different flowrates of counters are obtained from a set of simple calculating charts developed in this paper, which are recommended to China Standard GB5079 - 98.
Keywords:Cleanroom  technology  Aerosol sample  Particle counter  Permissible length of transit tube  