首页 | 本学科首页   官方微博 | 高级检索  
     

数字显示分光光度计中差示光度法的研究
引用本文:赵珍义 张新平. 数字显示分光光度计中差示光度法的研究[J]. 辽宁大学学报(自然科学版), 1993, 20(2): 62-64
作者姓名:赵珍义 张新平
作者单位:辽宁大学化学系,辽宁大学 八八届毕业生
摘    要:本文利用差示光度法的原理探讨了数字显示光度计中吸光度负值的理论根据,其中包括工作曲线的绘制,误差讨论。

关 键 词:分光光度计 差示光度法 负吸光度

A Study of Negative Absorbance on Digital Spectrophotometer
Zhao Zhenyi Zhang Cinping. A Study of Negative Absorbance on Digital Spectrophotometer[J]. Journal of Liaoning University(Natural Sciences Edition), 1993, 20(2): 62-64
Authors:Zhao Zhenyi Zhang Cinping
Affiliation:Zhao Zhenyi Zhang Cinping Department of Chemistry,Liaoning University
Abstract:In this paper the thecretical basis of applying the negative absorbance to digital spectrophotometer is discussed. The error analysis and the plotting of analytical curve are illustrated. It is shouvn that the application of negative absorbance will result in a wider analytical range. Smaller relative error and simpler operation.
Keywords:Spectrophotometry   Negative absorbance   Digital shectrophotometer.  