应用混凝土异型桩的地铁隔振交互试验研究
引用本文:刘晶磊,赵倩,赵小玉,刘桓,仉健.应用混凝土异型桩的地铁隔振交互试验研究[J].科学技术与工程,2018,18(32).
作者姓名:刘晶磊  赵倩  赵小玉  刘桓  仉健
作者单位:河北省土木工程诊断、改造与抗灾重点实验室,河北省土木工程诊断、改造与抗灾重点实验室,河北省土木工程诊断、改造与抗灾重点实验室,河北省土木工程诊断、改造与抗灾重点实验室,河北省土木工程诊断、改造与抗灾重点实验室
基金项目:河北省青年拔尖人才计划项目(项目编号:BJ2016018)
摘    要:为了研究地铁应用混凝土异型桩的减隔振效果,通过在地铁与建筑物之间设置混凝土异型桩进行减隔振缩尺模型交互试验,以振源深度、混凝土异型桩空心率以及其外截面形式3个因素为变量,分析了在地铁振动激励作用下建筑物各层竖向及水平向振动形态变化情况。结果表明:建筑物在地铁振动作用下,各楼层振幅降低比的大小呈现波浪形振动性态;混凝土异型桩具有明显减隔振效果,其中最优组合振幅降低比Ar为0.40,预期减振幅度可达59.58%;考虑影响减隔振效果的三因素以及因素之间的交互作用,其影响程度为:振源深度与空心率的交互作用影响高度显著;混凝土桩截面形式影响显著;空心率、振源深度及空心率与截面形式交互作用对试验结果有影响但影响不大。

关 键 词:    词:地铁  减隔振  异型桩  交互试验
收稿时间:2018/7/5 0:00:00
修稿时间:2018/9/3 0:00:00

Cross Experiment on Vibration Isolation of Subway Applied with Special-shaped Concrete Piles
LIU Jing-lei,ZHAO Xiao-yu,LIU Huan and ZHANG Jian.Cross Experiment on Vibration Isolation of Subway Applied with Special-shaped Concrete Piles[J].Science Technology and Engineering,2018,18(32).
Authors:LIU Jing-lei  ZHAO Xiao-yu  LIU Huan and ZHANG Jian
Institution:Hebei Key Laboratory for Diagnosis,Reconstruction and Anti-disaster of Civil Engineering,Hebei Zhangjiakou,,Hebei Key Laboratory for Diagnosis,Reconstruction and Anti-disaster of Civil Engineering,Hebei Zhangjiakou,Hebei Key Laboratory for Diagnosis,Reconstruction and Anti-disaster of Civil Engineering,Hebei Zhangjiakou,Hebei Key Laboratory for Diagnosis,Reconstruction and Anti-disaster of Civil Engineering,Hebei Zhangjiakou
Abstract:In order to investigate the vibration isolation effect of the special-shaped concrete piles applied between the subway and the adjacent building, a cross model experiment involved three factors, which are depth of vibration source, the hollow ratio of piles and the outer cross section was conducted. Meanwhile, being affected by the vibration of the subway, changes of perpendicular and horizontal modes of each building are analyzed. Experimental results show that the amplitude reduction ratio level of each floor of building presents a wavy condition under the vibration generated by subway; The concrete special-shaped piles have obvious effects on vibration reduction, which the optimal combination of amplitude reduction ratio Ar is 0.4 and anticipate results can be reached 59.58%; Consider three factors which influence the effect of vibration reduction and interaction between three factors, which could be as arranged the interaction between the depth of vibration source and hollow rate have great impact on the vibration isolation effect, and Concrete piles cross section form has significant impact, but there is little effect on the test results, which are hollow rate, vibration depth and the interaction between section form and hollow rate.
Keywords:Subway  Isolation  Shaped piles  Interaction tests