首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Mechanical and Experimental Study of Sprinkling Water Cooling System on Roof of Shanghai Expo Theme Pavilion
Authors:ZHAO Hui-zhong  HUANG Chen  LI Wei-xiang  SHI Jin-yue  TAO Si-yuan  WANG Qian  WANG Yu-qing  ZHANG Min
Abstract:Based on the similarity theory,a scale effect model of the spraying water cooling system of Shanghai expo Theme Pavilion's roof was set up.According to the typical weather conditions in Shanghai city,different models were analyzed on solar radiation,and different heat transfer amount was obtained.And the fol-lowing conclusions could be made:At the sunny day of summer in Shanghai,the temperature of inner roof with sprinkling system descended about 3℃,and the air conditioning load of the whole Theme Pavilion descend more than 320 kW.
Keywords:Shanghai expo  large space atrium  solar radiation  roof sprinkling system  similarity theory prototype