首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于制冷剂泄出的双温热泵特性研究
引用本文:武殿康,李风雷,王秀田,杜保存.基于制冷剂泄出的双温热泵特性研究[J].河北科技大学学报,2024,45(3):235-242.
作者姓名:武殿康  李风雷  王秀田  杜保存
作者单位:太原理工大学土木工程学院;山西四建集团有限公司
基金项目:国家自然科学基金(51906172);山西省重点研发计划项目(202102060301014);山西省基础研究计划项目(202103021224098);山西省住房和城乡建设厅科学技术计划项目(JJKJ2023015)
摘    要:为满足生产生活中双温供暖供热的需求,提出了一种基于制冷剂泄出的双温热泵系统。建立基于制冷剂泄出的涡旋压缩机数理模型和系统模型并进行数值模拟验证,计算分析系统在不同泄出口位置、泄出口大小、蒸发温度、高温冷凝温度、中温冷凝温度下系统各项性能参数的变化趋势,并与传统双温热泵系统进行对比分析。结果表明,压缩机中间泄出口打开越早压缩机耗功越少、泄出口越大系统节能效果越明显,较传统双温热泵系统制热性能系数在不同工况下都有显著提高,最高可提升16%。所提模型为制冷剂泄出式双温热泵、补气增焓热泵系统的理论分析提供了更有效方法,为涡旋压缩机性能优化和双温热泵系统的研究、设计及系统性能的提升提供了理论参考。

关 键 词:工程热力学  热泵  双温冷凝  涡旋压缩机  制冷剂泄出
收稿时间:2023/12/9 0:00:00
修稿时间:2024/3/2 0:00:00

Research on the characteristics of dual-temperature heat pump based on refrigerant leakage
WU Diankang,LI Fenglei,WANG Xiutian,DU Baocun.Research on the characteristics of dual-temperature heat pump based on refrigerant leakage[J].Journal of Hebei University of Science and Technology,2024,45(3):235-242.
Authors:WU Diankang  LI Fenglei  WANG Xiutian  DU Baocun
Institution:School of Civil Engineering University of Technology;China Shanxi Sijian Group Company Limited
Abstract:In order to meet the demand for dual-temperature heating in production and life, a dual-temperature heat pump system based on refrigerant leakage was proposed. By establishing and verifying the mathematical model and system model of the scroll compressor based on refrigerant leakage for numerical simulation, the system was calculated and analyzed under different discharge outlet positions, discharge outlet sizes, evaporation temperatures, high-temperature condensation temperatures, and medium-temperature condensation temperatures. The changing trends of performance parameters were compared with traditional dual-temperature heat pump systems. The results show that the sooner the middle discharge port of the compressor is opened, the less power the compressor consumes, and the larger the discharge port is, the more obvious the energy-saving effect of the system is; Compared with the traditional dual-temperature heat pump system, the heating performance coefficient is significantly improved under different working conditions, with the highest of 16%. The model proposed in the study provides a more effective method for the theoretical analysis of refrigerant leakage dual-temperature heat pumps and air-supplemented enthalpy-increasing heat pump systems, and the research results provide a theoretical basis for the optimization of scroll compressor performance, and the research, design and system performance improvement of dual-temperature heat pump systems.
Keywords:engineering thermodynamics  heat pump  dual temperature condensation  scroll compressor  refrigerant leakage
点击此处可从《河北科技大学学报》浏览原始摘要信息
点击此处可从《河北科技大学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏