首页 | 本学科首页   官方微博 | 高级检索  
     

离子色谱法同时测定饮用水中7种阴离子研究
引用本文:刘峰,马文琼,任红波,金海涛,单宏,张晓波,马永华. 离子色谱法同时测定饮用水中7种阴离子研究[J]. 哈尔滨商业大学学报(自然科学版), 2008, 24(5): 614-616
作者姓名:刘峰  马文琼  任红波  金海涛  单宏  张晓波  马永华
作者单位:黑龙江省农业科学院,农业部谷物及制品质量监督检验测试中心,哈尔滨150086;黑龙江省农业科学院,农业部谷物及制品质量监督检验测试中心,哈尔滨150086;黑龙江省农业科学院,农业部谷物及制品质量监督检验测试中心,哈尔滨150086;黑龙江省农业科学院,农业部谷物及制品质量监督检验测试中心,哈尔滨150086;黑龙江省农业科学院,农业部谷物及制品质量监督检验测试中心,哈尔滨150086;黑龙江省农业科学院,农业部谷物及制品质量监督检验测试中心,哈尔滨150086;黑龙江省农业科学院,农业部谷物及制品质量监督检验测试中心,哈尔滨150086
摘    要:研究化学抑制电导-离子色谱法同时测定饮用水中7种阴离子的分析方法.将水样经0.45μm微孔滤膜过滤,经过RP柱处理后连续进样,利用离子色谱仪ICS-3000同时测定F^-、Cl^-、NO2^-、Br^-、NO3^-、SO4^2-、PO4^3- 7种阴离子的浓度.试验采用IonPac AS11A分离拄和IonPac AG11A保护柱,淋洗液由淋洗液自动发生器产生,流速为1.2mL/min.保留时间的RSD为0.06%~0.59%,峰面积的RSD为1.06%~2.36%,各离子加标回收率为87.6%~105.7%,标准曲线的相关系数为0.9959~0.9998.该方法具有灵敏、准确、简便等优点,可用于饮用水中7中阴离子的同时分析.

关 键 词:离子色谱法  饮用水  阴离子

Determination of seven anions in drinking water by ion chromatography
LIU Feng,MA Wen-qiong,REN Hong-bo,JIN Hai-tao,SHAN Hong,ZHANG Xiao-bo,MA Yong-hua. Determination of seven anions in drinking water by ion chromatography[J]. Journal of Harbin University of Commerce :Natural Sciences Edition, 2008, 24(5): 614-616
Authors:LIU Feng  MA Wen-qiong  REN Hong-bo  JIN Hai-tao  SHAN Hong  ZHANG Xiao-bo  MA Yong-hua
Affiliation:LIU Feng,MA Wen-qiong,REN Hong-bo,JIN Hai-tao,SHAN Hong,ZHANG Xiao-bo,MA Yong-hua (Cereal , Products Quality Supervisory Inspection , Test Center,Heilongjiang Academy of Agricultural Sciences,Harbin 150086,China)
Abstract:To study a new method for quantitative detection of seven inorganic anions in drinking water including fluoride, chiorate, nitrite, bromate, nitrate, sulfate, phosphate at the same time. Dealing with RP column under the ion chromatography ICS -3000 with IonPac AS11A column and IonPac AG11A guard column, 7 inorganic anions in water samples are determined simultaneously after filtered with 0.45 μm filter membrane. The sampling is performed at a flow rate of 1.2 mL/min, eluent is generated by eluent generator, the method of chemically suppressed conductivity detection of seven inorganic anion in drinking water is an alternative to this method. The sample is treated with direct sampling. The RSD of retention time are from 0.06% to 0.59% , the RSD of peak area are from 1.06% to 2.36% and the recoveries are from 87.6% to 105.7% , the correlation coeffidient is from 0. 995 9 to 0. 999 8. The method proved to be high sensitive,accurate result and simply operation. It is adapt to determinate seven inorganic anions.
Keywords:ion chromatography  drinking water  inorganic anions  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号