首页 | 本学科首页   官方微博 | 高级检索  
     检索      

可变冷热流换热网络的夹点和最小外界供热调优
引用本文:徐亦方.可变冷热流换热网络的夹点和最小外界供热调优[J].中国石油大学学报(自然科学版),1989(5).
作者姓名:徐亦方
作者单位:石油大学 北京
摘    要:本文提出可变冷热流换热网络最小外界供热的调优启发式规则。给出了四种情况下的算法。对于普遍适用的可变冷热流最小外界供热问题,提出用可变容差法结合调优求解的算法。以常减压装置为例,调优后可使最小外界供热降为82.9%。表明多夹点常比单尖点可节省更多能量。

关 键 词:换热网络  夹点  调优  最小公用工程  门槛点

OPTIMIZATION OF MINIMUM UTILITY USAGE OF HEAT EXCHANGER NETWORK WITH VARIABLE HOT ANDLOR COLD STREAMS AND PINCH
Xu Yifang.OPTIMIZATION OF MINIMUM UTILITY USAGE OF HEAT EXCHANGER NETWORK WITH VARIABLE HOT ANDLOR COLD STREAMS AND PINCH[J].Journal of China University of Petroleum,1989(5).
Authors:Xu Yifang
Abstract:This paper proposes the heuristic rules for the optimization of minimum utility usage with variable hot and/or cold streams. Algorithms for four cases are given. Flexible tolerance method associated with optimization is suggested to be used for the general case. An example shows that this method can decrease minimum utility usage down to 82.9% and multi-pinches usually make lower minimum utility than single-pinch does.
Keywords:Heat exchanger network  Pinch  Optimization  Minimumutillty usage  Threshold point  
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号