摘    要: 以钴自给能探测器为例,详细阐述了瞬发型自给能中子探测器(SPND)与核反应堆内中子作用的物理特征、信号电流产生机理等关键过程,并借助于蒙特卡罗程序多粒子耦合输运功能对公开文献中的钴SPND初始灵敏度进行了理论分析计算。最后,将蒙特卡罗方法与确定论方法以及金箔活化法得到的实验测量值进行对比分析。结果表明,基于蒙特卡罗方法的理论计算值和实验值相比最大偏差皆小于5%,证明了该方法相较于确定论计算方法不仅更加简单有效,而且精度更高。

关 键 词:自给能中子探测器  钴-59  瞬时响应  中子灵敏度  蒙特卡罗方法
收稿时间:2022-07-08

Study on the initial sensitivity of prompt response self-powered neutron detector in Nuclear Reactor
WU Xiong,CAI Li,ZHANG Xiangju,LU Haoliang,JIANG Jieqiong. Study on the initial sensitivity of prompt response self-powered neutron detector in Nuclear Reactor[J]. Science & Technology Review, 2022, 40(24): 64-71. DOI: 10.3981/j.issn.1000-7857.2022.24.007
Authors:WU Xiong  CAI Li  ZHANG Xiangju  LU Haoliang  JIANG Jieqiong
Affiliation:1. Hefei Institute of Physical Science, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei 230031, China;
2. University of Science and Technology of China, Hefei 230026, China;
3. China Nuclear Power Technology Research Institute Co., Ltd., Shenzhen 518031, China
Abstract:In this paper, the prototype with Cobalt-59 emitter as a representative of instantaneous SPND was developed and modeled to calculate its initial sensitivity. This calculation model is based on Monte Carlo method of multi-particle coupling transportation. And some important details, such as the physical characteristics of cobalt SPND, the generation of signal current, were discussed thoroughly. The research results from this model are compared with experimental results by using gold foilactivation methods and show a very good agreement. The maximum relative error is not greater than 5%. It demonstrated that this method can be successfully applied in SPND calculation and better than determinism method.
Keywords:SPND  Cobalt-59  prompt feedback  neutron sensitivity  Monte Carlo method  