首页 | 本学科首页   官方微博 | 高级检索  
     检索      

密拼叠合板拼缝构造及受力性能试验研究
引用本文:何庆锋,胡程群,杨凯华,易伟建.密拼叠合板拼缝构造及受力性能试验研究[J].湖南大学学报(自然科学版),2022,49(3):111-122.
作者姓名:何庆锋  胡程群  杨凯华  易伟建
作者单位:湖南大学土木工程学院,湖南长沙410082;湖南大学工程结构损伤诊断湖南省重点实验室,湖南长沙410082,湖南大学土木工程学院,湖南长沙410082
摘    要:为了研究拼缝构造对密拼预应力钢筋混凝土叠合板受力性能的影响,提出一种增强型密拼缝构造,并设计了3组叠合板试件的抗弯性能试验.试验对各组试件的承载能力、刚度、破坏形态、裂缝和变形性能进行系统性研究,并分析拼缝叠合板的拼缝传力性能和预应力叠合楼盖的双向受力特性.试验结果表明:增强型密拼缝连接能够提高叠合板的垂直拼缝方向的抗...

关 键 词:密拼叠合板  预应力  承载能力  抗弯刚度  双向受力

Experimental Study on Joint Structure and Mechanical Performance of Densely Assembled Composite Slabs
HE Qingfeng,HU Chengqun,YANG Kaihu,YI Weijian.Experimental Study on Joint Structure and Mechanical Performance of Densely Assembled Composite Slabs[J].Journal of Hunan University(Naturnal Science),2022,49(3):111-122.
Authors:HE Qingfeng  HU Chengqun  YANG Kaihu  YI Weijian
Abstract:In order to study the effect of joint structure on the mechanical performance of densely assembled pre? stressed reinforced concrete composite slabs, an enhanced tight joint details is proposed, and the flexural tests of three groups of composite plates were designed. The test systematically studied the bearing capacity, stiffness, failure mode, crack and deformation performance of each group of specimens, and the joint force transmission performance of the jointed laminated slab as well as the two-way mechanical characteristics of the prestressed composite floor are analyzed. The test results show that the enhanced tight joint can improve the flexural stiffness of the composite slab in the vertical direction of the joint, its bearing capacity is close to that of the cast-in-place slab, and it can ensure the effective load transmission at the joint. The crack morphology at the joint position is good when the joint plate speci? men fails, and no tear damage occurs along the composite surface. The bearing capacity and deformation performance of the prestressed composite slabs are good. The mechanical performance test of the prestressed composite floor fur? ther shows that the composite slab with the reinforced joint structure can carry out two-way load transmission. An ul? timate bearing capacity formula of the prestressed composite floor was established based on the principle of virtual work. The calculated value of the ultimate load is good in agreement with the experimental value, which verifies the rationality of the assumed plastic hinge line mode. The strip method was used to verify the two-way mechanical per? formance of the prestressed composite floor.
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《湖南大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《湖南大学学报(自然科学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号