首页 | 本学科首页   官方微博 | 高级检索  
     

消解方法对ICP-MS法测定人发中微量元素含量的影响
引用本文:邱招钗. 消解方法对ICP-MS法测定人发中微量元素含量的影响[J]. 漳州师范学院学报, 2005, 18(1): 49-52,30
作者姓名:邱招钗
作者单位:厦门大学现代分析科学教育部重点实验室,福建厦门361005
摘    要:本文采用三种不同酸体系和两种加热方式组合成五种消解方法,对人发标准物质(GBW07601)进行消解,以ICP-MS作为分析技术测定其微量元素的含量,并对其方法、结果及影响因素进行了相应的讨论。

关 键 词:人发 微量元素含量 ICP-MS法 影响因素 测定 标准物质 消解方法 加热方式 分析技术
文章编号:1008-7826(2005)01-0049-04
修稿时间:2004-08-15

The different influence for the digestion methods to measure the content of multi-trace element in the human hair by ICP-MS
QIU Zhao-chai. The different influence for the digestion methods to measure the content of multi-trace element in the human hair by ICP-MS[J]. Journal of ZhangZhou Teachers College(Natural Science), 2005, 18(1): 49-52,30
Authors:QIU Zhao-chai
Abstract:Five digesting methods concluding three digesting acid systems and two heating modes were compared and discussed for the detection of multi-trace element concentrations in the standard material of human hair (GBW07601) by inductively coupled plasma mass spectrometry(ICP-MS),evaluate the accuracy of this method.And the accuracy of different methods was evaluated.