人工髋关节柄磨损评定中的三维表面形貌测量
引用本文:张洪玉,蒋向前,Blunt L,Brown L. 人工髋关节柄磨损评定中的三维表面形貌测量[J]. 应用基础与工程科学学报, 2012, 20(1): 139-148
作者姓名:张洪玉  蒋向前  Blunt L  Brown L
作者单位:1. 清华大学摩擦学国家重点实验室,北京100084;Centre for Precision Technologies,University of Huddersfield,Huddersfield, HD1 3DH, UK
2. Centre for Precision Technologies,University of Huddersfield,Huddersfield, HD1 3DH, UK
基金项目:中国博士后科学基金(20090460314,201003107);国家自然科学基金青年基金(51005130)
摘    要:论述了物体表面形貌的测量在工程上的重要性,指出了目前学术界与工业界所普遍采用的二维表面测量与评定的局限性,进而说明了三维表面测量的重大意义.在此基础上,将三维表面测量仪器,即接触式触针仪器、非接触式光学干涉仪以及原子力显微镜的原理、现状进行了分析比较.同时,对三维表面的评定技术及其三维表面参数,特别是伯明翰14参数的发展做了系统的论述.最后,以三维表面形貌测量在人工髋关节柄磨损评定中的应用为例,其结果表明,粗糙表面的髋关节柄和骨水泥之间的磨损为磨粒磨损,而抛光表面的髋关节柄和骨水泥之间的磨损为微动磨损,此为生物医学上进一步降低磨损微粒的产生、提高人工髋关节的寿命提供了重要参考.

关 键 词:三维测量  表面形貌  生物摩擦学  髋关节柄  摩擦磨损

The Application of 3D Surface Metrology in Characterization of Femoral Stem Wear
ZHANG Hongyu , JIANG Xiangqian , Blunt L , Brown L. The Application of 3D Surface Metrology in Characterization of Femoral Stem Wear[J]. Journal of Basic Science and Engineering, 2012, 20(1): 139-148
Authors:ZHANG Hongyu    JIANG Xiangqian    Blunt L    Brown L
Affiliation:ZHANG Hongyu1,2,JIANG Xiangqian2,BLUNT Liam2,BROWN Leigh2 (1.State Key Laboratory of Tribology,Tsinghua University,Beijing 100084,China;2.Centre for Precision Technologies,University of Huddersfield,Huddersfield,UK,HD1 3DH)
Abstract:The significance of three dimensional(3D)surface metrology in engineering is firstly discussed,based on the recognition of the limitation of two dimensional(2D)surface metrology that most researchers in academia and industry have been utilizing.Then a detailed description of modern 3D surface metrology instruments,i.e.contacting stylus,non-contacting optical interferometer and atomic force microscope,is given.Subsequently,the development of 3D surface characterization technique which concentrates mainly on 3D surface parameters,especially the famous Birmingham 14 Parameters,is introduced.Finally,a typical case study on the application of 3D surface metrology in characterization of femoral stem wear is proposed to further advocate the popularization of 3D surface metrology in biomedical engineering,with the result showing that matt femoral stems wear against bone cement by an abrasive mechanism whilst fretting wear dominates the wear mechanism between polished femoral stems and bone cement.
Keywords:three dimensional metrology  surface texture  biotribology  femoral stem  friction and wear