首页 | 本学科首页   官方微博 | 高级检索  
     

Spectroscopic Detection of Chiral Aggregation at Liquid-Liquid Interfaces
引用本文:Hitoshi Watarai Sayaka Wada Kazuhiko Fujiwara. Spectroscopic Detection of Chiral Aggregation at Liquid-Liquid Interfaces[J]. 清华大学学报, 2006, 11(2): 228-232. DOI: 10.1016/S1007-0214(06)70181-X
作者姓名:Hitoshi Watarai Sayaka Wada Kazuhiko Fujiwara
作者单位:Department of Chemistry Osaka University Osaka Japan,Department of Chemistry Osaka University Osaka Japan,Department of Chemistry Osaka University Osaka Japan
基金项目:Supported by the Grant-in-Aid for Scientific Research (No. 16105002) from the Ministry of Education, Science, Sports, and Culture, Japan
摘    要:Introduction Optical activity is a fundamental property, which pro-vides valuable information on the structure of mole-cules and the conformation of their assemblies. There-fore, it is widely used in many fields including organic chemistry, coordination c…

关 键 词:手性聚集 液-液界面 光谱测定 膜分离 循环二色性
收稿时间:2005-10-09
修稿时间:2005-10-09

Spectroscopic Detection of Chiral Aggregation at Liquid-Liquid Interfaces
Hitoshi Watarai, Sayaka Wada,Kazuhiko Fujiwara. Spectroscopic Detection of Chiral Aggregation at Liquid-Liquid Interfaces[J]. Tsinghua Science and Technology, 2006, 11(2): 228-232. DOI: 10.1016/S1007-0214(06)70181-X
Authors:Hitoshi Watarai   Sayaka Wada  Kazuhiko Fujiwara
Affiliation:Department of Chemistry, Osaka University, Osaka, Japan
Abstract:Two new spectroscopic methods to detect the optical activity of liquid-liquid interfaces have been developed. The first one is the centrifugal liquid membrane (CLM) method combined with a conventional cir-cular dichroism (CD) spectropolarimetry and the second one is a more interfacial specific second harmonic generation CD (SHG-CD) spectrometry. In the CLM-CD method, a cylindrical glass cell containing small amounts of organic and aqueous phases was rotated at about 7000 r/min in a sample chamber of a CD spectropolarimeter to generate an interface with a high specific interfacial area between the two-phase liquid membranes. The CD spectra of the J-aggregate of protonated 5,10,15, 20-tetraphenylporphyrin formed at the toluene-sulfuric acid interface have been measured. As for the SHG-CD, a circularly polarized wave-length-variable fs-laser system was constructed to measure the interfacial SHG spectra of a flat liquid-liquid interface. The ion-associated aggregation of a water-soluble anionic porphyrin promoted with a cationic am-phiphile at the heptane-water interface was observed by this technique and the observed SHG-CD spectra proved the generation of a characteristic optical activity accompanied by the formation of the interfacial ag-gregate of inherently achiral porphyrin molecules. These methods will pioneer a new field of interfacial chiral chemistry in the studies of solvent extraction mechanisms.
Keywords:chiral aggregation  liquid-liquid interface  spectroscopic detection  centrifugal liquid membrane  second harmonic generation circular dichroism
本文献已被 CNKI 维普 万方数据 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号