首页 | 本学科首页   官方微博 | 高级检索  
     

FBG传感器在PHC管桩水平载荷试验中的应用
引用本文:周薛淼,刘永,李国辉,韩高彬. FBG传感器在PHC管桩水平载荷试验中的应用[J]. 南华大学学报(自然科学版), 2015, 29(4): 109-112, 123
作者姓名:周薛淼  刘永  李国辉  韩高彬
作者单位:南华大学 核资源工程学院,湖南 衡阳 421001,南华大学 核资源工程学院,湖南 衡阳 421001,南华大学 核资源工程学院,湖南 衡阳 421001,中国水电基础局有限公司,天津 301700
基金项目:环保部科研基金资助项目(监管1409&1509)
摘    要:介绍了FBG传感器的优点,并说明了FBG传感器在PHC管桩中的安装工艺.结合实际工程,依据PHC管桩水平静载荷试验的监测结果,分析了PHC管桩桩身内力与变形的分布规律:在地面处,桩身弯矩接近于零,随着深度的增加,桩身弯矩呈现先增加后减小的趋势,其最大值在地面以下(1/12~1/6)桩长范围内发生,其弯曲变形主要发生在桩体上部1/3桩长范围,而距地面1/3桩长以下桩体几乎不发生弯曲变形;桩身挠度随深度的增加逐渐减小,最终减至零;水平荷载对桩身弯矩及挠度均有显著的影响.通过实验数据与理论计算结果的对比,可知FBG传感器测试数据精确、可靠,可较好的应用于PHC管桩的水平静载荷试验.

关 键 词:FBG传感器  PHC管桩  水平载荷试验  桩身内力  变形
收稿时间:2015-06-13

Application of FBG Sensing Technology in Lateral LoadTests on PHC Pipe Piles
ZHOU Xue-miao,LIU Yong,LI Guo-hui and HAN Gao-bin. Application of FBG Sensing Technology in Lateral LoadTests on PHC Pipe Piles[J]. Journal of Nanhua University(Science and Technology), 2015, 29(4): 109-112, 123
Authors:ZHOU Xue-miao  LIU Yong  LI Guo-hui  HAN Gao-bin
Affiliation:School of Nuclear Resources Engineering,University of South China,Hengyang,Hunan 421001,China,School of Nuclear Resources Engineering,University of South China,Hengyang,Hunan 421001,China,School of Nuclear Resources Engineering,University of South China,Hengyang,Hunan 421001,China and Sino Hydro Foundation Engineering Co.,Ltd.,Tianjin 301700,China
Abstract:The advantage of the FBG sensor was introduced and the FBG sensors installation process in PHC pipe piles was also proposed.Combined with practical engineering,according to the monitoring results of PHC pipe pile lateral static load tests horizontal,PHC pipe pile body force and deformation was analysed after data processing:On the ground,pile bending moment was closed to zero.With the increase of depth,bending showed a trend of decrease after the first increase,and the maximum was (1/12~1/6) pile under the ground.The bending deformation was mainly distributed in the pile length above 1/3 pile,and almost no deformation in the pile body below 1/3 pile;the deflection of the pile body decreases with increasing depth,and it was ultimately closed to zero;the horizontal load has significant impact on deflection of the pile body.Through comparing the experimental data with the theoretical calculation result,the testing data from the FBG sensor is reliable and could be better applied to the PHC pile lateral static load test.
Keywords:FBG sensors  PHC pipe pile  lateral static load tests  pile body internal force  deformation
本文献已被 CNKI 等数据库收录!
点击此处可从《南华大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《南华大学学报(自然科学版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号