首页 | 本学科首页   官方微博 | 高级检索  
     

ICP-MS法测定钼矿石中伴生锂、镓和稀土元素
引用本文:梁亚丽,杨珍,阿丽莉,贺攀红,孙银生. ICP-MS法测定钼矿石中伴生锂、镓和稀土元素[J]. 吉林大学学报(理学版), 2021, 59(2): 427-434. DOI: 10.13413/j.cnki.jdxblxb.2020316
作者姓名:梁亚丽  杨珍  阿丽莉  贺攀红  孙银生
作者单位:河南省核工业地质局, 郑州 450044; 河南省核工业放射性核素检测中心, 郑州 450044
基金项目:河南省国土资源厅两权价款地质科研项目
摘    要:通过比较氢氟酸-硝酸高压罐密闭消解法、氢氟酸-硝酸-高氯酸-盐酸低压密闭消解法和氢氟酸-硝酸-高氯酸-盐酸敞口消解法对钼矿样品的分解效果,选用低压密闭消解法制备样品,用电感耦合等离子体质谱(ICP-MS)法测定伴生稀有元素Li,Ga和15种稀土元素的质量比.通过对干扰元素的分析,选择合适同位素,并确定151 Eu,15...

关 键 词:电感耦合等离子体质谱法  密闭消解  钼矿石  伴生      稀土元素
收稿时间:2020-10-23

Determination of Associated Lithium,Gallium and Rare Earth Elements in Molybdenum Ore by Inductively Coupled Plasma Mass Spectrometry Method
LIANG Yali,YANG Zhen,A Lili,HE Panhong,SUN Yinsheng. Determination of Associated Lithium,Gallium and Rare Earth Elements in Molybdenum Ore by Inductively Coupled Plasma Mass Spectrometry Method[J]. Journal of Jilin University: Sci Ed, 2021, 59(2): 427-434. DOI: 10.13413/j.cnki.jdxblxb.2020316
Authors:LIANG Yali  YANG Zhen  A Lili  HE Panhong  SUN Yinsheng
Affiliation:Henan Province Nuclear Geology,Zhengzhou 450044,China;Henan Nuclear Industry Radioactive Nuclide Test Centre,Zhengzhou 450044,China
Abstract:By comparing the digestion effects of hydrofluoric acid-nitric acid high pressure tank closed digestion method, hydrofluoric acid-nitric acid-perchloric acid-hydrochloric acid low pressure closed digestion method and hydrofluoric acid-nitric acid-perchloric acid-hydrochloric acid open digestion method on molybdenum ore samples, the low pressure closed digestion method was selected to prepare samples, the inductively coupled plasma mass spectrometry  (ICP-MS) method was used to determine the mass ratio of associated rare elements lithium,  gallium and other 15  rare earth elements in molybdenum ore. Through the analysis of interfering elements, the suitable isotope was selected and the correction coefficients of 151Eu,157Gd,159Tb mass spectrum interference was determined. The results show that the standard solution of 20 μg/L rhodium is used as an internal standard solution can effectively inhibit matrix effect and signal dynamic drift in the solution,  the detection limit of the method is  0.001—0.113 μg/g,  and the relative standard deviation (RSD, n=7) is  0.30%—3.92%,  which is verified by standard materials and actual samples. The method is reliable and suitable for the determination of associated lithium,  gallium and rare earth elements in molybdenum ore.
Keywords:inductively coupled plasma mass spectrometry;   closed   digestion;   molybdenum ore;   associated;   lithium;   gallium;   rare earth element  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《吉林大学学报(理学版)》浏览原始摘要信息
点击此处可从《吉林大学学报(理学版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号