摘    要:中性点非有效接地配电网发生单相接地故障时,尽快选出故障线路对提高电网的供电可靠性有重要意义.文章综述了国内外小电流接地系统单相接地故障的保护现状,分析了目前各种保护原理的优点和不足.最后提出了自己的观点.

关 键 词:小电流接地系统  单相接地故障  故障选线  电磁暂态  消弧线圈  继电保护

Survey of the Faulty Feeder Selection Methods for Single-phase-to-earth Fault in Non-solid Grounded Networks
ZHANG Xin-hui. Survey of the Faulty Feeder Selection Methods for Single-phase-to-earth Fault in Non-solid Grounded Networks[J]. Journal of Zibo University(Natural Sciences and Engineering), 2002, 0(3): 43-46
Authors:ZHANG Xin-hui
Abstract:When single-phase-to-earth fault occurs on a neutral non-direct grounded power system,it is nexessary for improving the reliability of power supplying to select the faulted line quickly. The paper overviews the principle of single-plase-to-earth fault protection for small current neutral grounding at homt and abroad,and analyzes the advantages and disadvantages of the principles being used currently. Finally,it presents my view on single-lhase-to-earth fault protection.
Keywords:system with ungrounded neutral  single-phase-to-earth fault  fault line selection  electro-magnetic  arc suppressing coils  protective relaying