摘    要:通过分析全自动指示表检定仪在检定指示表示值误差时,光强和疲劳对测量结果的影响,进而制定光强、疲劳对检定结果影响程度的判定原则,并解决了检定仪在检定工作中存在的不确定性,最终提升了检定的准确性和有效性。

关 键 词:不确定性  全自动检定仪  光强  疲劳  示值误差

Study on Uncertainty about Verified Results Incarnated on Full-automatic Verifier Aerifier Applied to Indicating Meter
ZHANG Ling.Study on Uncertainty about Verified Results Incarnated on Full-automatic Verifier Aerifier Applied to Indicating Meter[J].Journal of Weifang University,2009,9(6):14-17.
Authors:ZHANG Ling
Institution:ZHANG Ling (Weifang University,Weifang 261061,China)
Abstract:The discussion includes the following respects: Firstly it is analysed that the Light-intensity and the fatigue are how to affect the verified results incarnated on full-automatic verifier applied to verify the error of indicated value incarnated on indicating meter;farthur the vevdict principle for the influence degree about verified results is constituted,and so on,the uncertainty existing in application on indicating meter is resolved;finally,the verification accuracy and effectiveness are promoted notably in application for verification.