首页 | 本学科首页   官方微博 | 高级检索  
     

寒区隧道地源热泵供热系统及优化分析
引用本文:张国柱,夏才初,孙猛,邹一川. 寒区隧道地源热泵供热系统及优化分析[J]. 同济大学学报(自然科学版), 2012, 40(4): 0610-0615
作者姓名:张国柱  夏才初  孙猛  邹一川
作者单位:同济大学地下建筑与工程系,上海200092;同济大学岩土及地下工程教育部重点实验室,上海200092
基金项目:国家自然科学基金项目(50878150),交通部西部交通建设科技资助项目(2009318822047),内蒙古自治区交通科技项目(NJ-2008-25)
摘    要:为解决寒区隧道冻害问题,将地源热泵型供热系统应用于内蒙古博牙高速林场隧道中.系统由取热段、加热段、热泵和分、集水管路组成,可用于隧道洞口段衬砌和排水系统加热.在分析研究该系统传热机理的基础上,建立考虑热阻和热源的隧道取热段传热模型,利用叠加原理、格林函数法和拉普拉斯变换法相结合的方法获得其解析解.热交换管间距对热交换管换热量有显著影响,随着管间距的增加,换热量呈线性增加.热交换管换热量随隧道埋深的增加而呈线性增加,热交换管应布置在埋深深的部位.与热泵持续运行相比,间歇运行有利于土壤温度场的恢复,有助于提高热泵运行效率.

关 键 词:寒区隧道  地源热泵  供热系统  优化分析
收稿时间:2011-02-27
修稿时间:2012-01-05

Tunnel Heating System with Heat Pump in Cold Region and Its Optimization
ZHANG Guozhu,XIA Caichu,SUN Meng and ZOU Yichuan. Tunnel Heating System with Heat Pump in Cold Region and Its Optimization[J]. Journal of Tongji University(Natural Science), 2012, 40(4): 0610-0615
Authors:ZHANG Guozhu  XIA Caichu  SUN Meng  ZOU Yichuan
Affiliation:Department of Geotechenical Engineering,Tongji Unversity,Department of Geotechenical Engineering,Tongji Unversity
Abstract:Tunnel heating system with heat pump was introduced for the first time at Linchang tunnel in Inner Mongolia Autonomous Region of China to prevent freezing damage in cold regions tunnels.Tunnel heating system consists of the heating section,absorbing section,heat pump,collector,and distributor line.This system can be used for heating lining and drainage system in tunnel portal.The heat transfer model of absorber pipes is obtained by considering thermal resistance and heat generation.The analytical solution can be obtained with the Green’s function method and Laplace transform technique.The distance of heat exchanger pipe has a great influence on specific energy output.With larger absorber pipes distance,the specific energy output of surrounding rock will increase linearly.The higher the ground temperature is,the greater the specific energy output of absorber pipes is.it is beneficial that the heat exchanger pipes should be placed in deeper depth of surrounding rock.Discontinuous operation of heat pump is good for the recover of soil temperature field around the heat exchanger pipes.Temperature increment between discontinuous and continuous operation presents an upward trend.Discontinuous operation is helpful to improve the coefficient of performance(COP) of heat pump.
Keywords:tunnel in cold region  heat pump  tunnel heating system  optimum analysis