An improved approach for the application of Trombe wall system to building construction with selective thermo-insulation façades
Authors:Ji  Jie  Luo  ChengLong  Sun  Wei  Yu  HanCheng  He  Wei  Pei  Gang
Institution:(1) Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei, 230026, China;(2) Qinghai Institute of Architectural Technology, Xining, 810012, China
Abstract:An improved Trombe wall is proposed to adapt to building construction with selective thermo-insula- tion façades (internal and cavity wall insulation, but not external wall insulation system). The case study is conducted in Xining, Capital city of Qinghai province in China, where the general building fa-çades are mostly selective thermo-insulation façades to fight against the severe cold. A numerical analysis is undertaken to show the effects on the improvement of the building’s thermal environment by comparing the improved Trombe wall system with the classical Trombe wall system. The operating efficiency of the improved Trombe wall can be up to 33.85%, an increase of 56%. The results show that the improved Trombe wall works more effectively than the classical Trombe wall system in utilizing solar energy for the sample building.
Keywords:passive solar heating  building  selective thermo-insulation façade  improved Trombe wall  classical Trombe wall
本文献已被 维普 SpringerLink 等数据库收录!
点击此处可从《中国科学通报(英文版)》浏览原始摘要信息