首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Investigation on phase-coded third harmonic imaging for normal and pathological tissues in transmission mode in vitro
作者姓名:MA  Qingyu  GONG  Xiufen  ZHANG  Dong  MA  Yong
作者单位:[1]State Key Laboratory of Modem Acoustics, Institute of Acoustics, Nanjing University, Nanjing 210093, China [2]Education Technique Department, Nanjing Normal University, Nanjing 210097, China
摘    要:Owing to the improved spatial resolution and the occurrence of fewer artefacts than the conventional ultrasonic imaging technique, ultrasonic nonlinear im-aging has attracted much attention in last two decades. The acoustic nonlinear effects in biological…

关 键 词:病理组织  成像传输方式  调谐  编码技术  信噪比
收稿时间:2005-08-26
修稿时间:2005-08-262005-11-28

Investigation on phase-coded third harmonic imaging for normal and pathological tissues in transmission mode in vitro
MA Qingyu GONG Xiufen ZHANG Dong MA Yong.Investigation on phase-coded third harmonic imaging for normal and pathological tissues in transmission mode in vitro[J].Chinese Science Bulletin,2006,51(10):1180-1184.
Authors:Qingyu Ma  Xiufen Gong  Dong Zhang  Yong Ma
Institution:(1) State Key Laboratory of Modern Acoustics, Institute of Acoustics, Nanjing University, Nanjing, 210093, China;(2) Education Technique Department, Nanjing Normal University, Nanjing, 210097, China
Abstract:In this paper, a phase-coded pulse technique is proposed to improve the signal-to-noise ratio (SNR) in the 3rd harmonic imaging in transmis-sion mode, where three pulses with initial phases of 0o, 120o and 240o are transmitted and their corre-sponding received signals are linearly summed. By means of simulations and measurements, we show that the 3rd harmonic is enhanced by 9.5 dB, whereas the fundamental or the 2nd harmonic components are suppressed; the axial and lateral beam profiles of the processed 3rd harmonics are superior to those of the fundamental or 2nd harmonic components. In addition, this technique is applied to obtain the 3rd harmonic images for two normal and pathological biological tissues in transmission mode. This technique yields a dramatically cleaner and sharper contrast than the images obtained by the traditional fundamental im-aging and the 2nd harmonic imaging, which helps distinguish the normal and pathological states of tis-sues.
Keywords:phase-coded technique  third order harmonic enhancement  pathological tissues  imaging in transmission mode  
本文献已被 维普 万方数据 SpringerLink 等数据库收录!
点击此处可从《中国科学通报(英文版)》浏览原始摘要信息
点击此处可从《中国科学通报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号