可溶有机试剂对ICP-AES测定水质铜的影响 |
| |
引用本文: | 赵阳,陈文,王湘君.可溶有机试剂对ICP-AES测定水质铜的影响[J].新乡学院学报(自然科学版),2011(6):513-514,518. |
| |
作者姓名: | 赵阳 陈文 王湘君 |
| |
作者单位: | 新乡市环境保护监测站;琼州学院理工学院;琼州学院生物科学与技术学院 |
| |
摘 要: | 通过对比三种有机试剂检测铜浓度变化的结果,得出了"采用含5%正丙醇溶液检测时仪器性能条件最佳"的结论.经相关参数的验证,证明此法的标准曲线线性良好,提高了灵敏度;计算得到的检出限为0.000 4 mg/L,低于现行标准;精密度为0.51%~1.1%,准确度为97.1%~105%,符合检测要求.为准确、有效地检测水中微量铜提供了新的方法.
|
关 键 词: | ICP-AES 铜 正丙醇 水质检测 |
The Effect of Soluble Organic Reagent to Copper in Water Determined by ICP-AES |
| |
Authors: | ZHAO Yang CHEN Wen WANG Xiang-jun |
| |
Institution: | 1.Xinxiang Environmental Protection Monitoring Station,Xinxiang 453002,China; 2.College of Science and Technical,Qiongzhou University,Sanya 572000,China; 3.College of Biological Science and Technology,Qiongzhou University,Wuzhishan 572200,China) |
| |
Abstract: | That "the solution contained 5% n-propyl alcohol is optimum condition for instrument detection performance" is obtained,through comparing detection results of copper concentration changes of three kinds of organic reagents.By related parameters validation,standard curve of the method has good linearity,and sensitivity was also increased.The detection limit calculated is 0.000 4 mg/L lower than the current standard.The precision and accuracy is 0.51%~1.1% and 97.1%~105% respectively,conform to determination requirements.It provides a new method to determine trace Copper in water accurately and effectively. |
| |
Keywords: | ICP-AES copper n-propyl alcohol water quality determination |
本文献已被 CNKI 维普 等数据库收录! |
|