气体泄漏红外成像检测系统的性能测试方法研究
引用本文:李家琨,金伟其,王霞,张旭,刘洋,夏润秋. 气体泄漏红外成像检测系统的性能测试方法研究[J]. 北京理工大学学报, 2016, 36(6): 630-634. DOI: 10.15918/j.tbit1001-0645.2016.06.015
作者姓名:李家琨  金伟其  王霞  张旭  刘洋  夏润秋
作者单位:北京理工大学 光电成像技术与系统教育部重点实验室, 北京 100081
基金项目:北京市自然科学基金重点资助项目(4121002)
摘    要:气体泄漏红外成像检测技术以其高效率遥测成像等显著优势成为气体泄漏检测的有效手段之一,针对此类系统探测能力的评价方法不全面的问题,通过改造MRTD测量靶标及方式,提出了适用于被动式气体红外成像检测系统性能的最小可分辨气体浓度MRGC (minimum resolvable gas concentration)评价方法,设计并搭建了MRGC性能测试系统,并以乙烯气体为检测目标进行了测试,测试结果与系统MRTD曲线的变化趋势具有较好的一致性. 

关 键 词:气体泄漏检测   红外成像   性能评价   MRGC   测试系统
收稿时间:2015-01-07

Research on Performance Measurement Method of Gas Leak Infrared Imaging Detection System
LI Jia-kun,JIN Wei-qi,WANG Xi,ZHANG Xu,LIU Yang and XIA Run-qiu. Research on Performance Measurement Method of Gas Leak Infrared Imaging Detection System[J]. Journal of Beijing Institute of Technology(Natural Science Edition), 2016, 36(6): 630-634. DOI: 10.15918/j.tbit1001-0645.2016.06.015
Authors:LI Jia-kun  JIN Wei-qi  WANG Xi  ZHANG Xu  LIU Yang  XIA Run-qiu
Affiliation:Key Lab of Photoelectronic Imaging Technology and System, Ministry of Education of China, Beijing Institute of Technology, Beijing 100081, China
Abstract:As a result of its significant advantages of high efficiency and remote imaging detection, gas leak infrared imaging detection technology has become one of the most effective means to detect gas leaks. This paper focuses on the performance measurement system of gas leak infrared imaging detection system. A novel minimum resolvable gas concentration(MRGC) evaluation method was proposed that was suitable for evaluating the performance of the passive gas leak infrared imaging detection system. The MRGC measurement system was designed and built. The measurement result, using ethylene as the target gas, and the minimum resolvable temperature difference (MRTD) curve were in good agreement, which sufficiently demonstrated the effectiveness of the MRGC performance evaluation method.
Keywords:gas leak detection  infrared imaging  performance evaluation  minimum resolvable gas concentration (MRGC)  measurement system
本文献已被 万方数据 等数据库收录!