调制DSC原理及其应用
引用本文:陈坚,杨永进,周庆华.调制DSC原理及其应用[J].实验室科学,2011,14(6):97-99,106.
作者姓名:陈坚  杨永进  周庆华
作者单位:苏州大学材料与化学化工学部,江苏苏州,215123
基金项目:国家人才培养模式创新实验区建设项目(2008); 苏州大学化学化工与材料学教学改革研究项目资助(2009)
摘    要:介绍调制温度式差示扫描量热仪(MDSC)技术的工作原理,并通过实例比较差示扫描量热仪(DSC)与调制温度式差示扫描量热仪(MDSC)两种测试技术的不同及MDSC的优点。

关 键 词:调制温度式差示扫描量热仪  热分析法  差示扫描量热仪

Principle and application of modulated differential scanning calorinetry
CHEN Jian , YANG Yong-jin , ZHOU Qing-hua.Principle and application of modulated differential scanning calorinetry[J].Laboratory Science,2011,14(6):97-99,106.
Authors:CHEN Jian  YANG Yong-jin  ZHOU Qing-hua
Institution:(College of Chemistry,Chemical Engineering and Materials Science,Soochow University,Suzhou 215123,China)
Abstract:The principle of modulated differential scanning(MDSC) was introduced firstly,and then the differences between general differential scanning calorinetry(DSC) and MDSC were analyzed by two examples.The results showed that MDSC had more advantages than general DSC.
Keywords:modulated differential scanning calorinetry(MDSC)  thermal analysis  differential scanning calorinetry(DSC)