摘    要:分析在万能工具显微镜上测头接触高度位置的调整误差,对斜齿轮分度圆螺旋角误差和齿向误差测量结果的影响,理论和实验结果表明,测头接触高度位置的变化地分度圆旋角误差测量结果没有影响,而对齿向误差测量结果的影响。

关 键 词:齿向误差 万能工具显微镜 测量 测头 齿轮

Effect of Adjustment Error of Gauge Head Position on the Measuring ResuIt of Tooth Curve Precision
Huang Fugui. Effect of Adjustment Error of Gauge Head Position on the Measuring ResuIt of Tooth Curve Precision[J]. Journal of Huaqiao University(Natural Science), 1997, 18(3): 275-278
Authors:Huang Fugui
Abstract:An universal tool-maker's microscopical analysis is given to the effect of the adjustment error of gauge head position. As shown by theoretical and experimental results, the position change of contacting height of gauge head in fluences the measuring result of tooth curve error;but it shows no effect on the measuring result of angle error of indexing circular helix.