带可更换连梁的双肢剪力墙抗震性能试验研究
引用本文:吕西林,陈云,蒋欢军.带可更换连梁的双肢剪力墙抗震性能试验研究[J].同济大学学报(自然科学版),2014,42(2):0175-0182.
作者姓名:吕西林  陈云  蒋欢军
作者单位:同济大学 土木工程防灾国家重点实验室;,同济大学土木工程防灾国家重点实验室,同济大学土木工程防灾国家重点实验室
基金项目:国家自然科学基金项目(51261120377),“十二五”国家科技支撑计划(2012BAJ13B02)
摘    要:设计了1个带有传统连梁的双肢剪力墙试件和1个带有可更换连梁保险丝的新型双肢剪力墙试件,通过低周反复加载试验对2个试件进行了抗震性能对比研究.研究表明,带有可更换连梁的新型剪力墙和传统剪力墙具有相同的承载力,其等效黏滞阻尼大于传统剪力墙,强度退化小,而且新型剪力墙能够将连梁的受损位置集中在保险丝,便于震后更换.

关 键 词:可更换连梁  保险丝  双肢剪力墙  低周反复加载试验  等效黏滞阻尼系数
收稿时间:2013/5/20 0:00:00
修稿时间:2013/10/28 0:00:00

Experimental Study of Seismic Performance of Coupled Shear Wall Structure with Replaceable Coupling Beams
LU Xilin,CHEN Yun and JIANG Huanjun.Experimental Study of Seismic Performance of Coupled Shear Wall Structure with Replaceable Coupling Beams[J].Journal of Tongji University(Natural Science),2014,42(2):0175-0182.
Authors:LU Xilin  CHEN Yun and JIANG Huanjun
Institution:State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University,State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University,State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University
Abstract:Over the past few years, the concept of providing fuses in coupling beams of shear walls has been developed and investigated by researchers around the world. The fuse is installed in the mid-span of coupling beam to dissipate seismic energy and is easy to be replaced in post-earthquake event. In the paper a conventional coupled shear wall specimen and a new coupled shear wall specimen with replaceable coupling beams were designed and tested by low cyclic loading tests. The seismic performance of two types of shear walls are studied and compared. The results show that the two specimens have similar bearing capacity. In addition, the new shear wall has larger equivalent viscous damping and displays less strength degradation. Moreover, the replaceable coupling beam of new shear wall make the structural damage concentrate in the fuses, while the other parts of replaceable coupling beams keep contact, which is beneficial to replace damaged fuse after the earthquake easily.
Keywords:replaceable coupling beam  fuse  coupled shear walls  low cyclic tests  equivalent viscous damping coefficient
本文献已被 CNKI 等数据库收录!