摘    要:隔河岩水电站压力隧洞是国内首次采用钢筋混凝土预应力衬砌结构,通过5年来对该结构的观测和资料分析表明,预应力在改善隧洞的结构应力和防止裂缝的产生方面效果显著,同时表明隔河岩采用后张法施加预应力是成功的,为今后大直径、高水头隧洞的设计和施工提供了新的途径和经验

关 键 词:隔河岩电站  压力隧洞  后张法  预应力

Behavior Analysis of Prestressed Liner for Pressure Tunnels of Geheyan Power Station
Zhou Jianjun,Wu Hanming,Guo Guilian.Behavior Analysis of Prestressed Liner for Pressure Tunnels of Geheyan Power Station[J].Journal of China Three Gorges University(Natural Sciences),1998(4).
Authors:Zhou Jianjun  Wu Hanming  Guo Guilian
Institution:Zhou Jianjun Wu Hanming Guo Guilian (Qingjiang Hydropower Corp.) (Dept. of Architectural Engineering) (Dept. of Electrical Engineering)
Abstract:Hennebique presterssed liner stuctures are used in pressure tunnels of Geheyan Power Station for the first time. Five years observation and data analysis indicate that there is a good result of improving the structural stresses of tunnels and avoiding producing cracks by use of prestress, and indicate that there in a good success in forcing prestress by post-tension. All of above will offer a new way and experience in the design of large-diameter and high waterhead in tunnel enginneering.