首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Application of Teleonic Principles in the Search for Systemic Causes of Accidents in Anesthesia
Authors:Járos  György  Baker  Barry B  Horváth  Gábor
Institution:(1) Department of Anaesthesia, The University of Sydney at Royal Prince Alfred Hospital, Sydney, Australia;(2) Department of General Computer Sciences, Eötvös Loránd University, Budapest, Hungary
Abstract:Safety of patients in anesthesia has always been one of the major concerns of the anesthetist. It is clear from studies of safety in general that many accidents and critical incidents occur as the result of latent systemic failures to which a great number of factors contribute (Reason, 1990). An ideal way to approach this problem would be within a systemic framework, such as teleonics, developed by Járos and his co-workers (Cloete, 1999; Járos and Cloete, 1987, 1993). In this framework the events and procedures in anesthesia are considered to be part of a very complex network of process systems (teleons). It is postulated that teleonic uncertainty (telentropy) in this complex network is a factor that might lead to accidents. In a previous paper presented to the World Congress at Toronto in 2000, the principles of teleonics were described in a mathematico symbolic way (Horváth et al., 2000). This paper contains selected examples of application of these principles to the identification of possible systemic causes of accidents in anesthesia.
Keywords:anesthesia  teleonics  process systems  accidents  safety
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号