超临界锅炉水冷壁爆管原因分析和预防措施
引用本文:高翔,贺卫国.超临界锅炉水冷壁爆管原因分析和预防措施[J].山西科技,2014(6):148-150.
作者姓名:高翔  贺卫国
作者单位:内蒙古京能电力检修有限公司,内蒙古乌兰察布,012000
摘    要:针对某电厂660 MW超临界锅炉水冷壁发生爆管的问题,分析了该故障产生的原因,认为水冷壁爆管为长期超温及短期严重过热所致,提出了处理故障的措施和预防水冷壁爆管的建议。

关 键 词:水冷壁爆管  故障分析  预防措施  超临界锅炉

Cause Analysis on and Prevention Measures for Supercritical Boiler Water Wall Tube Blasting
GAO Xiang,HE Weiguo.Cause Analysis on and Prevention Measures for Supercritical Boiler Water Wall Tube Blasting[J].Shanxi Science and Technology,2014(6):148-150.
Authors:GAO Xiang  HE Weiguo
Institution:GAO Xiang, HE Weiguo
Abstract:In the light of water wall tube blasting of 660 MW supercritical boiler in a causes of the fault, and holds that the fault was caused by the long-term overtemperature and puts forward some measures for treating the fault and some suggestions on preventing power plant, this paper analyzes the and short-term serious overheating, water wall tube blasting.
Keywords:water wall tube blasting  cause analysis  prevention measure  supercritical boiler