便携式分光光谱仪测定水中氯化物含量 |
| |
引用本文: | 赵楠. 便携式分光光谱仪测定水中氯化物含量[J]. 科技咨询导报, 2013, 0(33): 46-47 |
| |
作者姓名: | 赵楠 |
| |
作者单位: | 吉林市环境监测站,吉林省吉林市132001 |
| |
摘 要: | PORS-15浸入式便携分光光谱仪测定水中氯化物,与国家标准方法比对无显著差异。氯化物浓度在0.5~50mg/L范围内与吸光度呈线性关系,线性相关系数为r=0.998,加标回收率97%-106%,测定结果相对标准偏差1.8%~4.1%(n=6)。满足水质监测分析方法中对氯化物测定的限值要求。
|
关 键 词: | 氯化物 地表水 浸入式便携光谱仪 |
The Portable Spectrometer immersion chloride content in water |
| |
Abstract: | To use PORS-15 Portable Spectrometer immersion determine the chloride content in surface water,By comparison it has no significant deviation with the national standard method results.To show a good linear relationship between absorbance when the Chloride concentration in the range of 0.5-50mg/L,The linear correlation coefficient is r=0.998.The recovery is 97%-106%,The relative standard deviation of measured results isl.8%-4.1% (n=6).To content the Limit requirements of Determine chloride about analysis of surface water monitoring. |
| |
Keywords: | chloride surface water the Portable Spectrometer immersion |