降低线路电能损耗的中间供电法 |
| |
引用本文: | 刘福义.降低线路电能损耗的中间供电法[J].河北理工学院学报,2003,25(Z1):98-100. |
| |
作者姓名: | 刘福义 |
| |
作者单位: | 刘福义(开滦唐山矿业,公司机电科,河北,唐山,063000) |
| |
摘 要: | 在矿山供电系统中普遍都采取一端供电的方式,造成线路损耗及压降都很大.结合唐山矿业公司变电站供电系统的改造,提出由一端供电改为中间供电,达到了降低线路电能损耗及压降的效果.
|
关 键 词: | 一端供电 中间供电 电能损耗 压降 |
文章编号: | 1007-2829(2003)s0-0098-03 |
修稿时间: | 2003年6月8日 |
A middle power supply method to reduce the electric curcuit energy loss |
| |
Abstract: | In the mining power supplying system,it is common to supply power from one direction which makes high curcuit electric energy loss and voltage drop.Comparing with the change of power supplying system of Tangshan Mining transformer substation,this article gives the middle power supplying method more than one direction.This method has reduced the electric energy loss and voltagd drop. |
| |
Keywords: | power supplying from one direction middle power supplying electric energy loss voltage drop |