摘    要:基于导抗坏血酸定量还原Fe3+生成Fe2+的反应,以邻二氮菲为显色剂,建立了流动注射测定导抗坏血酸的新方法.方法的线性范围为0~2.0mg/l.可应用于锅炉给水除氧中异抗坏血酸的测定,结果满意.进行加标回收实验,回收率为98%~102%.

关 键 词:流动性注射分析,异抗坏血酸,锅炉给水测定

FIOW INJECTION DETERMINATION OF MICRO-AMOUNT OF ISO-ASCORBIC ACID N BOILER FEED-WATER
Zhang Zihong,Sun Ailing,Liu Guihua,Liu Daojie,Liu Renmin.FIOW INJECTION DETERMINATION OF MICRO-AMOUNT OF ISO-ASCORBIC ACID N BOILER FEED-WATER[J].Journal of Liaocheng University:Natural Science Edition,1994(1).
Authors:Zhang Zihong  Sun Ailing  Liu Guihua  Liu Daojie  Liu Renmin
Institution:Depar tment of Chemistry
Abstract:A new FIA method for iso-ascorbic acid in boiler feed-water has been developed,based on the quantitative reduction of Fe3 to Fe2 by iso-ascorbic acid. 1. 10-phenanthroline was used asthe color reagent. The linear range for the determination of iap-ascorbic acid is 0-2. 0mg/L. Theproposed method has been applied to the determination of iso-ascorbic acid in boiler feed-water with good results. Recovery of 98% -102% was obtained for standard addition determination.
Keywords:Flow injection anatysis  Iso-ascorbic acid  Boiler feed-water