Aging assessment of large generator insulation based on PD measurements
作者姓名:YUE Bo  CHEN Xiaolin  CHENG Yonghong  XIE Hengkun
作者单位:1. State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China; 2. Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China; 3. Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
基金项目:中国科学院资助项目,中国博士后科学基金,国家重点实验室基金
摘    要:The statistical parameters of phase resolved partial discharge (PD) distribution and ultra-wideband (UWB) characteristics of PD pulse are proposed for aging assessment of large generator insulation. Multi-stress aging tests of the model generator stator bar specimens were performed and PD measurements were conducted using both digital PD detector with frequency ranging from 40 kHz to 400 kHz and UWB PD detector with bandwidth from 10 MHz to 3 GHz at different aging stages. The test results show that the skewness and UWB frequency characteristics of PD can be taken as the characterization parameters for aging assessment of generator insulation. Furthermore, the measurement results of real generator stator bars show that these methods based on statistical parameters and UWB characteristics of PD are prospective for aging assessment and residual lifetime estimation of large generator stator insulation.

关 键 词:partial  discharge    stator  insulation    multi-stress  accelerated  aging    statistical  parameters    ultra-wideband    aging  assessment.

Aging assessment of large generator insulation based on PD measurements
YUE Bo,CHEN Xiaolin,CHENG Yonghong,XIE Hengkun.Aging assessment of large generator insulation based on PD measurements[J].Progress in Natural Science,2005,15(11):1035-1043.
Authors:YUE Bo  CHEN Xiaolin  CHENG Yonghong  XIE Hengkun
Institution:1. State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China;Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China;Department of Electrical Engineering, Tsinghua University,Beijing 100084,China
2. State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China
Abstract:The statistical parameters of phase resolved partial discharge (PD) distribution and ultra-wideband (UWB) characteristics of PD pulse are proposed for aging assessment of large generator insulation. Multi-stress aging tests of the model generator stator bar specimens were performed and PD measurements were conducted using both digital PD detector with frequency ranging from 40 kHz to 400 kHz and UWB PD detector with bandwidth from 10 MHz to 3 GHz at different aging stages. The test results show that the skewness and UWB frequency characteristics of PD can be taken as the characterization parameters for aging assessment of generator insulation. Furthermore, the measurement results of real generator stator bars show that these methods based on statistical parameters and UWB characteristics of PD are prospective for aging assessment and residual lifetime estimation of large generator stator insulation.
Keywords:partial discharge  stator insulation  multi-stress accelerated aging  statistical parameters  ultra-wideband  aging assessment