首页 | 本学科首页   官方微博 | 高级检索  
     

火焰原子吸收光谱法快速测定豆浆及其原料中的钙
引用本文:张丛兰,张 美,李 皓,杜 萍,马小建,李 庆,杨 芳. 火焰原子吸收光谱法快速测定豆浆及其原料中的钙[J]. 北京工商大学学报(自然科学版), 2013, 31(4): 23-27
作者姓名:张丛兰  张 美  李 皓  杜 萍  马小建  李 庆  杨 芳
作者单位:[1]湖北大学知行学院,湖北武汉430011 [2]武汉工程大学绿色化工过程省部共建教育部重点实验室,湖北武汉430073 [3]昆明理工大学分析测试研究中心,云南昆明650093 [4]云南省分析测试中心,云南昆明650093
基金项目:云南省科技条件平台建设计划项目(2010DH025); 广东省农业攻关项目(2012B020418003); 清远市产学研合作项目(2011D021113007)
摘    要:摘要:用火焰原子吸收光谱法测定豆浆及其原料中的钙.通过单因素实验,优化了样品的稀释比例和消化酸用量.研究了氧化钢溶液对豆浆中钙测定的影响.结果表明,优化的豆浆与水稀释体积比为1:3;10 mL稀释后豆浆和豆粉样品的消化酸用量分别为30 mL和35 mL;在豆浆加工中,钙的损失率为10.4%;加氧化钢后检测灵敏度达到0. 136μg/ ( mL·% ),检出限低至0.01 μg/mL,回收率为98.1 % .

关 键 词:豆浆  氧化钢    火焰原子吸收光谱法

Fast Determination of Calcium in Soybean Milk and Its Material by Flame Atomic Absorption Spectrometry
ZHANG Cong-lan,ZHANG Mei,LI Hao,DU Ping,A Xiao-jian,LI Qing and YANG Fang. Fast Determination of Calcium in Soybean Milk and Its Material by Flame Atomic Absorption Spectrometry[J]. Journal of Beijing Technology and Business University:Natural Science Edition, 2013, 31(4): 23-27
Authors:ZHANG Cong-lan  ZHANG Mei  LI Hao  DU Ping  A Xiao-jian  LI Qing  YANG Fang
Affiliation:1. Zhixing College of Hubei University, Wuhan 430011, China ; 2. Key Laboratory for Green Chemical Process of Ministry of Education, Wuhan Institute Technology, Wuhan 430073, China ; 3. Research Center for Analysis and Measurement, Kunming University of Science and Technology, Kunming 650093, China ; 4. Analytic and Testing Research Center of Yunnan, Kunming 650093, China)
Abstract:Abstract: The calcium concentrations in soybean milk and its material were determined by flame atomic absorption spectrometry ( FAAS). The optimal dilution ratio of soybean milk and the amount of digestion acid were discussed by single-factor experiments. Effect of Lanthanum oxide solution on the determination of calcium in soybean milk was also studied. The results showed that the optimizing dilution ratio of soybean milk was 1 : 3 ; the digestion acid consumption of soybean milk and soybean meal was 30 mL and 35 mL, respectively. The addition of lanthanum oxide resulted in the better sensitivity (0. 136 μg/(mL·% ) ), lower detection limits(0.01 μg/mL), and higher recovery(98. 1% ). The calcium concentration decreased 10.4% in the soybean milk processing.
Keywords:soybean milk  lanthanum oxide  calcium  flame atomic absorption spectrometry
本文献已被 维普 等数据库收录!
点击此处可从《北京工商大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《北京工商大学学报(自然科学版)》下载全文