首页 | 本学科首页   官方微博 | 高级检索  
     检索      

配电变电站典型接线的可靠性非同调元件辨识
引用本文:纪静,谢开贵,曹侃,胡博.配电变电站典型接线的可靠性非同调元件辨识[J].重庆大学学报(自然科学版),2012,35(3):74-80.
作者姓名:纪静  谢开贵  曹侃  胡博
作者单位:重庆大学 输配电装备及系统安全与新技术国家重点实验室,重庆 400044;重庆大学 输配电装备及系统安全与新技术国家重点实验室,重庆 400044;重庆大学 输配电装备及系统安全与新技术国家重点实验室,重庆 400044;重庆大学 输配电装备及系统安全与新技术国家重点实验室,重庆 400044
基金项目:国家自然科学基金资助项目(50777067、51077135);输配电装备及系统安全与新技术国家重点实验室自主研究项目(2007DA10512709103);重庆市杰出青年基金项目(CSTC2010BA3006);重庆大学研究生科技创新基金资助项目(CDJXS11150001)
摘    要:由于配电变电站接线形式、断路器等设备可靠性参数及负荷水平等因素,电力系统中可能存在可靠性非同调元件。辨识出可靠性非同调元件并使其退出运行可有效改善系统可靠性。给出了配电变电站可靠性非同调的定义,以及可靠性非同调概率、频率及非同调电量等指标用以描述系统的可靠性非同调程度,基于变电站电气主接线可靠性评估原理给出配电变电站非同调元件辨识方法。理论分析和算例表明:配电变电站高压侧母联断路器在单台变压器容量满足负荷需求时可能成为可靠性非同调元件,且断路器等设备可靠性参数对系统可靠性非同调特性具有一定影响。

关 键 词:可靠性  非同调  变电站主接线  非同调元件辨识  非同调指标

Recognizing the reliability non-coherence components ofdistribution substation typical configuration
JI Jing,XIE Kai gui,CAO Kan and HU Bo.Recognizing the reliability non-coherence components ofdistribution substation typical configuration[J].Journal of Chongqing University(Natural Science Edition),2012,35(3):74-80.
Authors:JI Jing  XIE Kai gui  CAO Kan and HU Bo
Institution:State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University, Chongqing 400044, P.R.China;State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University, Chongqing 400044, P.R.China;State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University, Chongqing 400044, P.R.China;State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University, Chongqing 400044, P.R.China
Abstract:Reliability non-coherence components (RNC) may exist in a power system due to the effects of distribution substation connection modes, components reliability performance, load level, and other factors. Recognizing RNCs and removing them from a power system can improve system reliability. The reliability non-coherence phenomenon is analyzed and the reliability non-coherence probability, frequency and energy indices, which can describe the degree of the system reliability non-coherence feature, are proposed. Based on the reliability evaluation theory of substation configuration, recognizing technique of RNCs of distribution substation is proposed. The theoretical analysis and example show that the breaker connects high voltage buses may be the RNC when the rated capacity of one transformer can meet the load requirement, and the reliability parameters of breakers have some effects on the reliability non-coherence features of the typical substation configuration.
Keywords:reliability  non-coherence  substation configuration  non-coherence component recognizing  non-coherence indices
点击此处可从《重庆大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《重庆大学学报(自然科学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号