基于同步挤压小波变换的配电网单相高阻接地故障选线
引用本文:韩 笑,罗维真,王春蘅.基于同步挤压小波变换的配电网单相高阻接地故障选线[J].科学技术与工程,2019,19(15):150-156.
作者姓名:韩 笑  罗维真  王春蘅
作者单位:南京工程学院江苏省主动配电网重点建设实验室,南京,211100;南京工程学院江苏省主动配电网重点建设实验室,南京,211100;南京工程学院江苏省主动配电网重点建设实验室,南京,211100
基金项目:江苏省研究生科研与实践创新计划基金
摘    要:为提高配电网单相接地故障选线的成功率,提出了一种基于同步挤压小波变换的配电网单相高阻接地故障选线新方法。该算法首先通过同步挤压小波变换方法确定各馈线的最大时频脊线,计算最大时频脊线下的挤压能量和挤压相角。在此基础上,通过闵可夫斯基距离来表征每条线路的故障特征,并以此特征区别接地与非接地馈线。仿真实验结果显示,该选线算法受故障位置,过渡电阻,初始角度,馈线结构等因素的影响较小,能够准确地识别故障线路。对比其他已知算法,该算法对电流信号的处理精度更高,能更好适应复杂的配电网系统。

关 键 词:高阻接地故障  同步挤压小波变换  最大时频脊线  挤压能量  挤压相角
收稿时间:2019/1/8 0:00:00
修稿时间:2019/5/23 0:00:00

High-Impedance Grounding Fault selection inthe Distribution Network Using Synchrosqueezed Wavelet Transforms
Han Xiao,and.High-Impedance Grounding Fault selection inthe Distribution Network Using Synchrosqueezed Wavelet Transforms[J].Science Technology and Engineering,2019,19(15):150-156.
Authors:Han Xiao  and
Institution:Nanjing Institute of Technology(Jiangsu Province Active Distribution Network Key Construcion Laboratory,,
Abstract:In order to improve the success rate of the High-Impedance Grounding Fault (HIGF) selection, a new algorithm is proposed to work in HIGF Selection. By using Synchrosqueezed Wavelet Transforms (SWT), the maximum time-frequency ridge of each feeders was analyzed first. Then the synchrosqueezed energy and the synchrosqueezed angle of each feeders are calculated to characterize the feature of each feeder by utilizing Minkowski distance. The fault and non fault line can be distinguished based on the feature. According to the simulation result, this algorithm is little influenced by the fault location, ground resistance, initial phase angle, feeder structure, etc. The fault line can be selected accurately. Comparing with other available algorithms,this new algorithm has higher accuracy and better adaptation in complex distribution network.
Keywords:high-impedance grounding fault  synchrosqueezed wavelet transforms  maximum time-frequency ridge  synchrosqueezed energy  synchrosqueezed angle