首页 | 本学科首页   官方微博 | 高级检索  
     

Equilibrium Copper Strip Points as a Function of Temperature and Other Operating Parameters: Implications for Commercial Copper Solvent Extraction Plants
引用本文:Gary Kordosky Michael Virnig Burrel Boley. Equilibrium Copper Strip Points as a Function of Temperature and Other Operating Parameters: Implications for Commercial Copper Solvent Extraction Plants[J]. 清华大学学报, 2006, 11(2): 160-164. DOI: 10.1016/S1007-0214(06)70170-5
作者姓名:Gary Kordosky Michael Virnig Burrel Boley
作者单位:Burrel Boley Cognis Corporation Tucson Arizona USA,Burrel Boley Cognis Corporation Tucson Arizona USA
摘    要:Introduction Copper solvent extraction (SX) is a well known proc-ess for copper recovery from a wide variety of leach solutions. Until recently, typical leach solutions con-tained 0.5 to 8 g/L Cu at 15 to 25℃ . In the past 5 years there has been signific…

关 键 词:溶剂萃取 炼铜 生物浸出 湿法冶金
收稿时间:2005-10-09
修稿时间:2005-10-09

Equilibrium Copper Strip Points as a Function of Temperature and Other Operating Parameters: Implications for Commercial Copper Solvent Extraction Plants
Gary Kordosky, Michael Virnig,Burrel Boley. Equilibrium Copper Strip Points as a Function of Temperature and Other Operating Parameters: Implications for Commercial Copper Solvent Extraction Plants[J]. Tsinghua Science and Technology, 2006, 11(2): 160-164. DOI: 10.1016/S1007-0214(06)70170-5
Authors:Gary Kordosky   Michael Virnig  Burrel Boley
Affiliation:Cognis Corporation, Tucson, Arizona, USA
Abstract:The development of pressure and bioleaching processes for high grade copper ores and concentrates will result in copper solvent extraction plants treating solutions with high copper and acid concentrations at temperatures up to 45°C and these copper solvent extraction plants will run with reagent concentrations up to 40 vol.%. There is also a trend to use copper stripping solutions with less acid than typically used in recent years. Cognis has developed a model that accurately predicts the copper strip point for virtually any copper solvent extraction reagent or combination of reagents under a wide variety of conditions. The equilibrium strip points for several well known commercial copper solvent extraction reagents are given as a function of reagent concentration, the copper and acid concentration of the strip aqueous, and the temperature. It is shown that the equilibrium strip point is not a straight line function of reagent concentration and that the equilibrium strip point increases with an increase in temperature. Copper extraction also increases as the temperature increases.
Keywords:equilibrium strip point  solvent extraction plants  bioleaching process
本文献已被 CNKI 维普 万方数据 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号