首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Sealed model and computation of hazardous waste landfill high voltage DC leakage detection
Abstract:According to the structural characteristics of hazardous waste landfill and the leakage current model of high voltage DC Landfill leakage detection,a sealed model is established and analyzed in detail.The detection layer of the hazardous waste landfill is considered as a sealed space and it is assumed that the source current flows through the leak entirely.The leak is regarded as a positive current resource +I located at the current entrance or a negative resource-I located at the current exit,which depends on the placement of the current supply.The electrical potential of an arbitrary in detection layer satisfies Poisson equation.The boundary condition is regarded as a natural boundary condition for the high resistivity of high density polyethylene(HDPE) membrane.Based on which a numerical calculation method is developed.Satisfactory agreement between experimental data and simulated data validates the analysis.Parametric studies show that a larger horizontal distance between the power supply electrode and leak and a smaller distance between the detector electrodes and the detected liner are helpful to leak location.More parametric curves show that parameters leaks can be detected effectively with optimum selection of field survey.
Keywords:
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号