首页 | 本学科首页   官方微博 | 高级检索  
     检索      

数值积分函数对超声波流量计精度的影响
引用本文:陈强,李伟华,吴婷,吴江涛.数值积分函数对超声波流量计精度的影响[J].西安交通大学学报,2012,46(9):21-25.
作者姓名:陈强  李伟华  吴婷  吴江涛
作者单位:西安交通大学热流科学与工程教育部重点实验室,710049,西安
基金项目:国家高技术研究发展计划资助项目(2009AA05Z107)
摘    要:针对数值积分函数在超声波流量计计量过程中会引入固有误差的问题,对常用的4种积分函数在Re为1.0×103~1.0×107区间的固有误差进行了比较.通过建立超声波流量计数学模型,结合发展管内流速的分布规律,计算各积分函数的2~5个声路的误差,得到了误差分布曲线.研究结果表明:各积分函数的声路数越多,引入的固有误差越小,当Re大于等于1.0×105时,各积分函数的引入误差随着Re的增大逐渐趋于稳定.在声路数不受限制且管路流量检测范围内会出现最大引入误差时,Gauss-Legender积分具有明显优势.当Re大于等于8.0×103、小于等于4.0×105时,Tailored积分具有较小误差,而Owics积分更适用于声路数受限制和Re大于4.0×105的管路流量检测.

关 键 词:超声波流量计  数值积分  误差分析

Influence of Numerical Integration on Error of Ultrasonic Flowmeter
CHEN Qiang , LI Weihuang , WU Ting , WU Jiangtao.Influence of Numerical Integration on Error of Ultrasonic Flowmeter[J].Journal of Xi'an Jiaotong University,2012,46(9):21-25.
Authors:CHEN Qiang  LI Weihuang  WU Ting  WU Jiangtao
Institution:(MOE Key Laboratory of Thermo-Fluid Science and Engineering,Xi’an Jiaotong University,Xi’an 710049,China)
Abstract:Comparative research was carried out on the inherent error of four commonly used inherent in the Reynolds number interval 1.0×103-1.0×107 according to the inherent error introduced by the numerical integration of ultrasonic flowmeters during the measuring process.From the mathematical model of an ultrasonic flowmeter and the universal velocity distribution of a fully developed pipe flow,the error of integrations of a flowmeter with two to five acoustic paths was calculated,and the error distribution curves were obtained.The results show that inherent error introduced by the integration decreases with an increase in the number of acoustic paths.When the Reynolds number is higher than 1.0×105,all the integrations’ importing error is gradually stable.However,Gauss-Legender has obvious advantages when the number of acoustic paths is unlimited and the maximum importing error occurs in the flow detecting range.Tailored has a smaller error than the others in the Reynolds number range of 8.0×103-4.0×105.Owics is more suitable for the flow measurement where the number of acoustic paths is limited and the Reynolds number is higher than 4.0×105.
Keywords:ultrasonic flowmeter  numerical integration  error analysis
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号