摘    要:利用有限时间热力学分析理论,对新型双级耦合热泵供暖系统建立了存在热阻、热漏、内不可逆损失的恒温定常流热力学循环模型,得到系统供热性能最优结果下,最佳传热面积分配,最佳工质工作温度,最小总传热面积以及最小输入功率的解析式.结合实际算例的计算结果,详细分析了各不可逆因素对系统性能的影响.所得结论为新系统在实际推广过程中的设计、运行提供了一定理论依据.

关 键 词:双级热泵  热力学分析  性能优化
文章编号:1005-0930(2007)02-0235-09
修稿时间:2005-11-042007-04-10

Finite Time Thermodynamic Optimization of the Double-stage Coupled Heat Pumps
WANG Wei,MA Zuiliang.Finite Time Thermodynamic Optimization of the Double-stage Coupled Heat Pumps[J].Journal of Basic Science and Engineering,2007,15(2):235-243.
Authors:WANG Wei  MA Zuiliang
Institution:1. The College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100022, China; 2. School of Municipal and Environmental Engineering,Harbin Institute of Technology, Harbin 150090, China
Abstract:Finite time thermodynamic optimization theory was applied to optimize the performance of the double-stage coupled heat pumps heating system(DSCHP).The irreversible steady flow model of the DSCHP system was founded considering heat resistance,heat leak and internal irreversibility.The optimal allocation of heat exchanger area for DSCHP that maximized the objective function(Coefficient of performance) was investigated.The optimal temperatures of the working fluids,the minimum total heat exchanger area and the minimum power input were determined in terms of the analytical expressions.The effects of the three irreversible factors on the system optimal performance were discussed by calculating some practical cases.The optimization results could guide the design and operation process for the DSCHP system.
Keywords:double-stage heat pumps  thermodynamic analysis  performance optimization