首页 | 本学科首页   官方微博 | 高级检索  
     

GC6型气相色谱仪应用中遇到的问题及处理
引用本文:张波. GC6型气相色谱仪应用中遇到的问题及处理[J]. 潍坊学院学报, 2003, 3(6): 55-56
作者姓名:张波
作者单位:潍坊学院,山东,潍坊,261061
摘    要:CC6型在线气相色谱仪使用中,在设计上由于采样管线过长,样品更新慢。导致滞后时间太长。对此进行了故障的分析和采样系统的改造。取得了满意的效果。

关 键 词:GC6型气相色谱仪 采样管线 滞后时间 故障分析 技术改造 采样系统
文章编号:1671-4288(2003)06-0055-02
修稿时间:2003-05-05

The Problem and the Transform Measure about the Gas Chromatographic Analysis Instrument GC6 Type in it''''s Application
ZHANG Bo. The Problem and the Transform Measure about the Gas Chromatographic Analysis Instrument GC6 Type in it''''s Application[J]. Journal of Weifang University, 2003, 3(6): 55-56
Authors:ZHANG Bo
Abstract:The gas chromatographic analysis instrument of the type GC6 is used in the process control system, because of the design for sampling system is not suitable, the delay time is very large. By the analysis of the problem and the transform for sampling system, the good results have been achieved.
Keywords:sampling system  the time delay  chromatograpllic analysis  decompress  transform