Numerical simulation of temperature field in horizontal core-filling continuous casting for copper cladding aluminum rods |
| |
Authors: | Ya-jun Su Xin-hua Liu Yong-fu Wu Hai-you Huang Jian-xin Xie |
| |
Institution: | 1784. Key Laboratory for Advanced Materials Processing (Ministry of Education), Institute of Advanced Materials and Technology, University of Science and Technology Beijing, Beijing, 100083, China
|
| |
Abstract: | The steady-state temperature field of horizontal core-filling continuous casting (HCFC) for producing copper cladding aluminum rods was simulated by finite element method to investigate the effects of key processing parameters on the positions of solid-liquid interfaces (SLIs) of copper and aluminum. It is found that mandrel tube length and mean withdrawing speed have significant effects on the SLI positions of both copper and aluminum. Aluminum casting temperature (T Al) (1003–1123 K) and secondary cooling water flux (600–900 L·h?1) have little effect on the SLI of copper but cause the SLI of aluminum to move 2–4 mm. When T Al is in a range of 1043–1123 K, the liquid aluminum can fill continuously into the pre-solidified copper tube. Based on the numerical simulation, reasonable processing parameters were determined. |
| |
Keywords: | |
本文献已被 万方数据 SpringerLink 等数据库收录! |
| 点击此处可从《矿物冶金与材料学报》浏览原始摘要信息 |
| 点击此处可从《矿物冶金与材料学报》下载免费的PDF全文 |