首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Correlations of Two-phase Friction of Refrigerant in Horizontal Smooth Tube with 2.5 mm inside Diameter
作者姓名:魏文建  丁国良  王凯建
作者单位:Insitute of Refrigeration and Cryogenics Shanghai Jiaotong University Shanghai 200030,Insitute of Refrigeration and Cryogenics,Shanghai Jiaotong University Shanghai 200030,Insitute of Refrigeration and Cryogenics,Shanghai Jiaotong University Shanghai 200030,Fujitsu General Institute of Air-Conditioning Technology Limited,Kawasaki,Japan
摘    要:IntroductionReduction of the refrigerant charge in refrigeratingsystems is a significant mechanismfor mini mizing refrigerantleakage , which results in a worldwide redirection oftransport phenomena research and development ,from macroscale (conventional) to micro scale equipments . The use of aphysically small heat exchanger for a given capacity isadvantageous for several reasons : smaller evaporatorssignify the reduction of the plant size ; small physical sizeoften i mplies relatively lower m…

关 键 词:制冷剂  流动沸腾  摩擦  管材
收稿时间:2004-09-14

Correlations of Two-phase Friction of Refrigerant in Horizontal Smooth Tube with 2.5 mm inside Diameter
WEI Wen-jian,DING Guo-liang,WANG Kai-jian.Correlations of Two-phase Friction of Refrigerant in Horizontal Smooth Tube with 2.5 mm inside Diameter[J].Journal of Donghua University,2006,23(1):78-83.
Authors:WEI Wen-jian  DING Guo-liang  WANG Kai-jian
Abstract:Two-phase flow pressure drop measurements are made during phase change heat transfer process of R-22 in small horizontal smooth tubes with 2. 5 mm inside diameter.Conclusions are drawn that the quality corresponding to pressure gradient peak value of small tubes became higher than that of large tubes and that effects of quality on pressure drop become weak as the increase of mass flux.The experiment data are compared with predicted values of the state-of-the-art correlations from the open literature,which indicates that most of the state-of-the-art correlations fail to predict the present experimental data. Chisholm model shows a relatively better predictive ability than the other empirical correlations because it has the lowest mean deviation of 26.7%. But the predicted values of Chisholm model are 50% lower than experimental data when quality becomes higher. In this regard, an new empirical correlation based on Chisholm model is developed and this modified Chisholm correlation can describe 95% of the present data with ± 20% mean deviations.
Keywords:refrigerant  flow boiling  pressure drop performance  small tube