摘    要:考察了基体对待测稀土杂质元素信号的影响,讨论了内标对基本效应的补偿作用,对于不同的基体元素最佳的内标元素是不一致的,Ga,In,I,Cs和T1是稀土纯度分析中合适的内标元素,内标法简便易行,效果好,其测定方法的精度和回收率令人满意。

关 键 词:电感耦合等离子体质谱法 高纯稀土 稀土杂质 基体效应
文章编号:1001-7542(2001)02-0036-03
修稿时间:2000-10-19

Matrix Effect in the Determination of Rare Earth Impurities by Inductively Coupled Plasma Mass Spectrometry
YAN E. Matrix Effect in the Determination of Rare Earth Impurities by Inductively Coupled Plasma Mass Spectrometry[J]. Journal of Qinghai Normal University(Natural Science Edition), 2001, 0(2): 36-38
Authors:YAN E
Abstract:This Paper has discussed the effect of matrix on the signal for rare earth impurities to be determined and also studied the compensation of internal standard for the matrix effect.For different matrix elements,the optimum internal elements are inconsistent.Ga,In,I,Cs and T1 are stuitable internal standard elements in the analysis of high puity rare earths.Internal standard method is simple and effective,its precision and recoveries are statisfactory.