SDG-Based HAZOP and Fault Diagnosis Analysis to the Inversion of Synthetic Ammonia |
| |
Authors: | L Ning WANG Xiong |
| |
Affiliation: | Department of Automation, Tsinghua University, Beijing 100084, China |
| |
Abstract: | This paper presents some practical applications of signed directed graphs (SDGs) to computeraided hazard and operability study (HAZOP) and fault diagnosis, based on an analysis of the SDG theory. The SDG is modeled for the inversion of synthetic ammonia, which is highly dangerous in process industry, and HAZOP and fault diagnosis based on the SDG model are presented. A new reasoning method, whereby inverse inference is combined with forward inference, is presented to implement SDG fault diagnosis based on a breadth-first algorithm with consistency rules. Compared with conventional inference engines, this new method can better avoid qualitative spuriousness and combination explosion, and can deal with unobservable nodes in SDGs more effectively. Experimental results show the validity and advantages of the new SDG method. |
| |
Keywords: | signed directed graph (SDG) synthetic ammonia hazard and operability study (HAZOP) fault diagnosis |
本文献已被 CNKI 维普 万方数据 ScienceDirect 等数据库收录! |
|