摘    要:在分析电阻分压器性能影响因素的基础上,仿真分析了电感补偿、供给式电容补偿、收集式电容补偿及综合补偿的补偿效果.加入套筒电极的收集式补偿措施,更适用于小型电阻分压器的性能改善.介绍了小型收集式补偿电阻分压器的结构设计,试验对比验证了其补偿效果.仿真优化显示,该分压器阶跃响应的上升时间(10%~90%)能够降低7 ns,达到1 ns以内.并对分压器的双指数脉冲响应进行了仿真分析和试验,结果表明,分压器准确测量双指数脉冲的前提是分压器阶跃响应的上升时间小于被测脉冲的上升时间,且没有过冲.

关 键 词:电阻分压器  双指数脉冲  阶跃响应  纳秒脉冲测量
文章编号:1001-0505(2006)03-0374-06
收稿时间:2005-12-15
修稿时间:2005-12-15

Performance of resistance divider and measurement of high-voltage nanosecond double exponential pulse
Chen Weifeng,Jiang Quanxing. Performance of resistance divider and measurement of high-voltage nanosecond double exponential pulse[J]. Journal of Southeast University(Natural Science Edition), 2006, 36(3): 374-379
Authors:Chen Weifeng  Jiang Quanxing
Affiliation:College of Mechanical Engineering, Southeast University, Nanjing 210096, China
Abstract:Based on the analysis of influence factors of resistance divider performance, the counterbalance effects of inductance, supplying distributed capacitance and collecting distribution capacitance were analyzed by simulation. The divider structure counterbalanced by collecting distribution capacitance was designed. Its counterbalance effect was validated by measurement practically. Simulation results show that its rise time of step response can be reduced by 7 ns, to be less than 1 ns. Responses of resistance divider on double exponential pulse were also analyzed and tested. Experiment and simulation results show that to make an accurate measurement the step response rise time of divider must be less than the rise time of double exponential pulse waiting for measurement and the step response wave form must be no any overshoot.
Keywords:resistance divider  double exponential pulse  step response  nanosecond pulse measurement
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号