首页 | 本学科首页   官方微博 | 高级检索  
     

钢铁企业氧气系统动态仿真
引用本文:陈光,陆钟武,蔡九菊,卜庆才. 钢铁企业氧气系统动态仿真[J]. 东北大学学报(自然科学版), 2002, 23(10): 940-943
作者姓名:陈光  陆钟武  蔡九菊  卜庆才
作者单位:东北大学材料与冶金学院;东北大学材料与冶金学院;东北大学材料与冶金学院;东北大学材料与冶金学院辽宁沈阳110004;辽宁沈阳110004;辽宁沈阳110004;辽宁沈阳110004
基金项目:国家重点基础研究发展规划项目 (G2 0 0 0 0 2 6 30 0 ),安徽省教育基金项目( 2 0 0 0J.2 .190 )
摘    要:分析了钢铁企业氧气发生、储存和使用的特点,建立了氧气系统动态数学模型,开发了调试简单的氧气仿真系统,并对一个联合钢铁企业氧气系统进行了实例计算·实例仿真计算结果表明:生产能力比平均使用量大得越多,PID调节越有效;工作压力、管网体积、炼钢用氧作业模式,对氧气放散率影响十分明显·最大工作压力提高04MPa,放散率减少53%;管网体积增加3750m3,放散率减少16%;1号转炉的作业曲线向前平移28h,放散率减少了20%·

关 键 词:氧气动态平衡  制氧机  作业模式  仿真  PID调节  氧气放散
文章编号:1005-3026(2002)10-0940-04
修稿时间:2002-03-21

Dynamic Simulation of Oxygen Supply System in Iron and Steel Company
CHEN Guang,LU Zhong wu,CAI Jiu ju,BU Qing cai. Dynamic Simulation of Oxygen Supply System in Iron and Steel Company[J]. Journal of Northeastern University(Natural Science), 2002, 23(10): 940-943
Authors:CHEN Guang  LU Zhong wu  CAI Jiu ju  BU Qing cai
Abstract:A dynamic model of oxygen supply and consumption system in iron and steel company was set up by the analysis of the oxygen production, deposit and usage. The simulation software of oxygen system was designed by a simple debugging method. An oxygen system of integrated iron and steel company was taken as example to calculate. The results show that the bigger the difference between capability and output is, the more effective the PID control is. The pipe net pressure, volume and converter oxygen operation programs affect the oxygen release ratio very much. The oxygen release ratio decreases by 5 3% with the pipe net pressure increasing by 0 4?MPa, decreases by 1 6% with the volume increasing by 3?750?m 3,and decreases by 2 0% with converter oxygen operation programme moving forward 2 8?h.
Keywords:dynamic balance of oxygen  oxygen making machine  operation time program  simulation  PID adjusting  oxygen release
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《东北大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《东北大学学报(自然科学版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏