首页 | 本学科首页   官方微博 | 高级检索  
     

Pilot Study on Drinking Water Advanced Treatment by GAC-MF System
引用本文:王欣泽,薛罡,王宝贞,王琳. Pilot Study on Drinking Water Advanced Treatment by GAC-MF System[J]. 东华大学学报(英文版), 2004, 21(1): 135-139
作者姓名:王欣泽  薛罡  王宝贞  王琳
作者单位:[1]SchoolofEnvironmentalScienceandEngineering,ShanghaiJiaotongUniversity,Shanghai,200240 [2]CollegeofEnvironmentalScienceandEngineering,DonghuaUniversity,Shanghai,200051 [3]SchoolofMunicipal&EnvironmentalEngineering,HarbinInstituteofTechnology,Harbin,150090
基金项目:Sponsored by Fok Ying Tung Education Foundation (No. 94004)
摘    要:The pilot pedomance of the combined GAC-MF membrane process for drinking water advanced treatment was described. In the process of GAC adsorption, under the conditions of 20min HRT and 6 m/h filtration rate, the removal efficiencies of UV254 and trichloromethane could reach 40% and 50% respectively and the UV254 and trichloromethane in system effluent was less than 0.015cm^-1 and 5 μg/L respectively. Inthe post MF membrane process, MF membrane effectively retained the particles and bacteria in raw water. The effluentturbidity was less than 0.2 NTU and no bacteria were detectedat all in permeate. A computer-controlled system was employedto control this system. The mcmlrane operating parameters of backwash interval, dtration and flux were studied. The backwash interval of 10-min, 20-min and 60-min wasresearched respectively, and the variation of trans-membrane pressure was also analyzed. Comequently short backwash interval was recommended under the same water consume.

关 键 词:粒状活性炭吸附 MF膜 飞行员 高级水处理 饮用水标准 除菌

Pilot Study on Drinking Water Advanced Treatment by GAC-MF System
WANG Xin-ze XUE Gang,WANG Bao-zhen,WANG Lin School of Environmental Science and Engineering,Shanghai Jiaotong University,Shanghai, School of Municipal , Enviromnental Engineering,Harbin Institute of Technology,Harbin, College of Environmental Science and Engineering,Donghua University,Shanghai. Pilot Study on Drinking Water Advanced Treatment by GAC-MF System[J]. Journal of Donghua University, 2004, 21(1): 135-139
Authors:WANG Xin-ze XUE Gang  WANG Bao-zhen  WANG Lin School of Environmental Science  Engineering  Shanghai Jiaotong University  Shanghai   School of Municipal & Enviromnental Engineering  Harbin Institute of Technology  Harbin   College of Environmental Science  Engineering  Donghua University  Shanghai
Affiliation:1. School of Environmental Scienceand Engineering, ShanghaiJiaotong University, Shanghai, 200240;School of Municipal & Environmental Engineering, Harbin Institute of Technology, Harbin, 150090
2. College of Environmental Science and Engineering, Donghua University, Shanghai, 200051
3. School of Municipal & Environmental Engineering, Harbin Institute of Technology, Harbin, 150090
Abstract:The pilot performance of the combined GAC-MF membrane process for drinking water advanced treatment was described. In the process of GAC adsorption, under the conditions of 20 min HRT and 6 m/h filtration rate, the removal efficiencies of UV254 and trichloromethane could reach 40% and 50%respectively and the UV254 and trichloromethane in system effluent was less than 0.015 cm-1 and 5 μg/L respectively. In the post MF membrane process, MF membrane effectively retained the particles and bacteria in raw water. The effluent turbidity was less than 0.2 NTU and no bacteria were detected at all in permeate. A computer-controlled system was enployed to control this system. The membrane operating parameters of backwash interval, duration and flux were studied. The backwash interval of 10-min, 20-min and 60-min was researched respectively, and the variation of trans-membrane pressure was also analyzed. Consequently short backwash interval was recommended under the same water consume.
Keywords:granular activated carbon adsorption   MF membrane   drinking water advanced treatment
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号