纤维液膜萃取分离器的流动、传质规律研究
引用本文:范怡平,尤明扬,鄂承林,李涛子,卢春喜,顾春来,时铭显.纤维液膜萃取分离器的流动、传质规律研究[J].中国石油大学学报(自然科学版),2006,30(6):107-111.
作者姓名:范怡平  尤明扬  鄂承林  李涛子  卢春喜  顾春来  时铭显
作者单位:1. 中国石油大学,重质油加工国家重点实验室,北京,102249
2. 北京欣博通创新能源技术开发有限公司,北京,100083
基金项目:中国石油化工股份有限公司基础理论研究资助项目
摘    要:在一直径为70mm,高为2630mm的有机玻璃纤维液膜萃取分离器冷态实验装置上考察了操作参数及结构参数对其传质性能和流动特征的影响。通过考察体积传质系数,确定了纤维液膜萃取分离器的最佳填充密度和最佳流量比。建立了流动模型,提出了以无量纲准则数雷诺数为设计纤维液膜萃取分离器的准则。实验结果表明,其最佳填充密度为2.8%~3%,最佳操作流量比为5。

关 键 词:纤维液膜  萃取分离器  流动  传质  填充密度  流量比  雷诺数  设计
收稿时间:2006-09-18

Flow and mass-transfer laws in a fiber film extractor
FAN Yi-ping,YOU Ming-yang,E Cheng-lin,LI Tao-zi,LU Chun-xi,GU Chun-lai,SHI Ming-xian.Flow and mass-transfer laws in a fiber film extractor[J].Journal of China University of Petroleum,2006,30(6):107-111.
Authors:FAN Yi-ping  YOU Ming-yang  E Cheng-lin  LI Tao-zi  LU Chun-xi  GU Chun-lai  SHI Ming-xian
Institution:1. State Key Laboratory of Heavy Oil Processing in China University of Petroleum, Beijing 102249, China ; 2. New Baron Innovative Energy Technology Development INC, Beijing 100083, China
Abstract:The performances of the fiber film extractor were investigated using a cold plexiglass pipe of 70 mm in diameter and 2 630 mm in height, The influences of the operating and structural parameters on the flow and mass-transfer characteristics of the fiber film extractor were revealed. By analyzing the volume mass-transfer coefficient, the optimal operating flow-ratio and packed density were obtained. A flow model was built. Moreover, based on the theoretical analysis, Renault number was proposed as the design principle dimensionless number for fiber film extractor design purpose. The experimental results indicate that the optimal operating flow-ratio for a fiber film extractor is 5 while the best packed density is 2.8% - 3%.
Keywords:fiber film  extractor  flow  mass transfer  packed density  flow ratio  Renault number  design